(1) Touch-sensitive LCD
This screen displays various information, and is used for automatic operation,
data entry, and other operations.
When the backlight of the touch-sensitive LCD goes out, the screen
turns completely black and you can no longer see what is on the screen.
The touch switches, however, are enabled. When nothing is displayed
on the LCD screen even though the power LED is ON, the backlight
may have gone out. Stop to use it immediately and repair the Operator
WARNING
Panel.
(2) Function switches
These switches are used for entering data from the Operator Panel.
(3) EMERGENCY STOP switch
This switch is for Emergency Stop. When this switch is pressed, the
Emergency Stop state is held both mechanically and electrically. When an
emergency stop is performed, the motor for each manipulator axis turns OFF
and the robot stops immediately.
For details on how to release an Emergency Stop, refer to 1.3 Emergency Stop.
Immediately press the EMERGENCY STOP switch whenever you
suspect any danger.
The Operator Panel is equipped with an EMERGENCY STOP switch.
Before operating the Operator Panel, make sure that the EMERGENCY
STOP switch on the Operator Panel functions properly. Operating the
Operator Panel when the switch does not function properly is extremely
WARNING
hazardous and may result in serious bodily injury and/or serious
damage to the equipment, as the switch cannot fulfill its intended
function in an emergency.
(4) Power LED
This LED lights (green) when the controller's power switch is turned ON.