Supermicro SC815B Chassis Series User's Manual

System Cooling

Fans

Four 4-cm counter-rotating fans provide the cooling for the system. Each fan unit is actually
made up of two fans joined back-to-back, which rotate in opposite directions. This counter-
rotating action generates exceptional airflow and works to dampen vibration levels.
Make sure the chassis top cover makes a good seal so air circulates properly through the
chassis. Note: There are four fans installed, and two optional (with dummy spacers).
Changing a System Fan
1. Determine which fan is failing. If possible, use the Baseboard Management Controller
(BMC), see your motherboard manual. Remove the chassis cover to examine the fans.
2. Power down the system and remove both cords from both power supplies. Remove the
chassis from the rack and seat it on a work bench (safety area). Then open the chassis
cover as described in section 3.2.
3. Remove the power cable of the failed fan from the motherboard.
4. Hold down fan housing with one hand and use the other to lift up the failed fan from the
housing and out of the chassis.
5. Place the replacement fan into the vacant space in the housing while checking proper
orientation. Ensure the mounting pins are secured in the housing.
6. Connect the fan power cable to the motherboard.
7. Confirm the fans are working properly before closing the chassis cover.
Figure 3-3. Fan Positions
26