ART� 337
Mains voltage (U1)
Mains fuse (delayed action)
Max power consumption
Cutting current range
Cutting current 10 min/40°C (IEC 60974-1)
Open-circuit voltage (U0)
working temperature
transport and storage temperature
CEBORA torches
Cutting current (I2)
Cutting voltage (U2)
Max. actual supply current (I1 eff max)
Mains voltage tolerance
Mains frequency
Mains connection Zmax @ U1=400 V
performance @ U1=400 V
Consumption in an inactive state
Overvoltage class
Degree of pollution (IEC 60664-1)
Degree of protection IP
Cooling type
Electromagnetic compatibility class
Max. gas inlet pressure
Marking
Dimensions WxDxH
Weight
NOTE:
After consulting the above table, size the power source electrical supply panel as appropriate. If using a three-phase
400 V electrical panel with 32 A sockets, reduce the cutting current to 120 A.
34
208 V
220 V
50 A
22,0 kVA
20 ÷ 130 A
105 A @ 100 %
125 A @ 60 %
130 A @ 50 %
345 V
365 V
-10°C ÷ 40°C
-25°C ÷ 55°C
CP70C / CP162C
50 A
50/60 Hz
-
-
-
-
-
-
0,9 MPa / 9 bar / 130 psi
297 mm x 613 mm x 558 mm
230 V
400 V
32 A
125 A @ 100 %
130 A @ 80 %
382 V
334 V
130 A
160 V
34 A
± 10%
≤ 22 mΩ
-
-
≥ 85 %
≤ 50 W
-
III
3
IP23S
AF
A
CE S
40 kg
440 V
365 V
-
-
-

Advertisement

Table of Contents
loading

This manual is also suitable for:

336337

Table of Contents