Mitsubishi Electric i-BX-N Technical Manual page 5

Table of Contents

Advertisement

TM_i-BX(-N)_NC05_00_06_20_EN
4.9.2.2
4.9.2.3
Regulation based on the external temperature starting from version NC04.00 relC50 .............................................................. 42
4.9.3
.....
Activation of the pressure safety control ...............................................................................................................................................42
4.10
..
UNIT PUMP MANAGEMENT ........................................................................................................................................................................43
4.10.1
...
General ..................................................................................................................................................................................................43
4.10.2
...
Pump in continuous operation ...............................................................................................................................................................43
4.10.3
Pump in sniffer mode .............................................................................................................................................................................43
...
4.11
..
ELECTRIC HEATER AT THE DELIVERY ....................................................................................................................................................44
4.11.1
Replacement heater ..............................................................................................................................................................................44
...
4.11.2
...
Integration heater ..................................................................................................................................................................................44
4.11.3
Antifreeze heater ...................................................................................................................................................................................46
...
4.11.4
...
Defrost heater ........................................................................................................................................................................................46
4.12
ALTERNATIVE HEAT SOURCE (BOILER) .................................................................................................................................................46
..
4.12.1
...
Replacement heat source......................................................................................................................................................................46
4.12.2
...
Integration heat source ..........................................................................................................................................................................47
4.13
..
ANTIFREEZE PROTECTION ........................................................................................................................................................................48
4.13.1
...
Exchanger antifreezee...........................................................................................................................................................................48
4.13.2
...
System primary circuit antifreeze ..........................................................................................................................................................49
4.13.3
...
System secondary circuit antifreeze ......................................................................................................................................................49
4.13.4
...
Room temperature antifreeze (only with zones active) .........................................................................................................................50
4.13.5
DHW storage tank antifreeze ................................................................................................................................................................51
...
4.14
..
DEFROST ......................................................................................................................................................................................................51
4.15
..
HEAT PUMP INHIBITIONS ...........................................................................................................................................................................53
4.15.1
...
Operation outside envelope...................................................................................................................................................................53
4.15.2
...
External air temperature ........................................................................................................................................................................53
4.15.3
...
External air temperature and water temperature ...................................................................................................................................54
4.16
..
DEMAND LIMIT .............................................................................................................................................................................................55
4.17
..
TRAY HEATER .............................................................................................................................................................................................55
4.18
..
CURRENT OPERATION MODE NOTIFICATION ........................................................................................................................................55
4.19
NIGHT FUNCTION ........................................................................................................................................................................................56
..
5 ......... MANAGEMENT OF DOMESTIC HOT WATER (DHW) ...................................................................................... 57
5.1
....
MANAGEMENT OF THE DHW 3-WAY VALVE ...........................................................................................................................................57
5.2
DHW STORAGE TANK MANAGEMENT .....................................................................................................................................................58
....
5.2.1
.....
Heat pump only .....................................................................................................................................................................................58
5.2.2
.....
DHW storage tank heater only ..............................................................................................................................................................59
5.2.3
.....
HP + DHW storage heater (P0202=3) or delivery heater (P0202=1 and P0300=1) .............................................................................60
5.3
....
LOW ENERGY TARIFF.................................................................................................................................................................................62
5.4
....
ANTI-LEGIONELLOSIS ................................................................................................................................................................................62
6 ......... HARDWARE ....................................................................................................................................................... 63
7 ......... HARDWARE ARCHITECTURE .......................................................................................................................... 64
7.1
....
ADDRESSING OF THE MODBUS MASTER COMMUNICATION MODULES ............................................................................................64
7.2
PSD1 OR PSD2 DRIVER ADDRESS CONFIGURATION ............................................................................................................................64
....
8 ......... INPUT / OUTPUT CONFIGURATION TABLE .................................................................................................... 65
8.1
....
AIR / WATER INVERTER UNIT WITH DHW MANAGEMENT (WITH 3-WAY VALVE) ..............................................................................65
8.2
I-BX CHILLER ONLY NON-REVERSIBLE INVERTER AIR/WATER UNITS ..............................................................................................67
....
9 ......... ANNEXES ........................................................................................................................................................... 68
9.1
....
PID REGULATION ........................................................................................................................................................................................68
9.1.1
Proportional Action ................................................................................................................................................................................68
.....
9.1.2
.....
Integral Action ........................................................................................................................................................................................68
9.1.3
Derivative Action ....................................................................................................................................................................................69
.....
9.1.4
.....
The combined effect of the three actions ..............................................................................................................................................69
9.2
PSD2 POWER+ INVERTER USE .................................................................................................................................................................70
....
MEHITS S.p.A.
TECHNICAL MANUAL
5
Version NC05 - Translation of the Original Instructions

Advertisement

Table of Contents
loading

This manual is also suitable for:

I-bx

Table of Contents