Gas Heat Operation; Dry-Air Operation; Auto Change Over Operation - Airxcel RVP INFRARED REMOTE CONTROL SYSTEM Operating Instructions Manual

Table of Contents

Advertisement

B.

GAS HEAT OPERATION

(If gas heat appliance is connected to upper unit)
Gas Heat symbol
1.
Select gas heat by pressing the "MODE" button until the gas heat symbol is
displayed.
2.
Set temperature to the desired level by pushing the up(+) or down(-) button.
C.

DRY-AIR OPERATION

Dry-air symbol
1.
Select the dry-air mode by pressing the "MODE" button until the dry-air
symbol is displayed.
2.
Set temperature to the desired level by pushing the up(+) or down(-) button.
3.
In the dry-air mode, the compressor & fan will cycle on and off at different
timing intervals depending on the setpoint. If the temperature is above the
setpoint, the on cycle is longer than the off cycle to help maintain setpoint. If
the temperature is below the setpoint, the off cycle is longer than the on cycle
to help maintain setpoint.
D.

AUTO CHANGE OVER OPERATION

Auto change symbol
1.
Select the auto change over mode by pressing the "MODE" button until the
auto change symbol is displayed.
2.
Set temperature to the desired level by pushing the up(+) or down(-) button.
(Note: In the auto change over mode the unit will maintain a comfortable
temperature throughout the room without the trouble of having to select heat
or cool mode. A gas heat appliance and air conditioner must be present and
operational before this feature can operate.)
6