Airxcel Aqua-Hot Reporter 400 Series Use And Care Manual
Hide thumbs Also See for Aqua-Hot Reporter 400 Series:

Advertisement

Quick Links

Use and Care Guide
400
Series
AHE-450-DE5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Aqua-Hot Reporter 400 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Airxcel Aqua-Hot Reporter 400 Series

  • Page 1 Use and Care Guide Series AHE-450-DE5...
  • Page 2 Journey in Comfort Thank you for equipping your RV, coach, or caravan with an Aqua-Hot hydronic heating system! We deeply value your business and we are grateful for the trust you have placed with Aqua-Hot Heating Systems, LLC. Our customers are our top priority and we are committed to providing best-in-class products, service, and support.
  • Page 3: Table Of Contents

    Journey in Comfort Introduction Contents Caution Notes As you read this information, take particular note of the NOTICE, Caution Notes ............3 CAUTION, WARNING, and DANGER symbols when they appear. Safety Features ............4 This information is important for safe and efficient use of the Aqua-Hot system.
  • Page 4: Safety Features

    Safety Instructions Safety Instructions System Overview Safety Features System Overview Read all instructions before operating the Aqua-Hot unit. Aqua- Important Notes: Hot Heating Systems is not liable for damage resulting from failing to follow instructions contained in this, and any other Low-Voltage Shutdown The Aqua-Hot 450D is a Hydronic (water-based) Heating •...
  • Page 5: System Features

    Aqua-Hot System Features Component Callouts System Features 14. Wiring Harness Port 1. Drain Valve The Aqua-Hot Heating System is a Low Emissions Hydronic 15. Aqua-Hot Reporter 2. Zone 1 Circulation Pump Heating System (heating with hot water) that significantly improves your level of comfort, decreases harmful emissions 16.
  • Page 6: Controls Overview

    Activating the Aqua-Hot Controls Overview Activating the Aqua-Hot Hot Water System Controls Overview Heating Operation: Domestic Hot Water System operating temperature. Be sure to activate the electric element switch for maximum water capacity. The heating features are powered by a 12V DC diesel burner General Information: and a 120V AC electric element.
  • Page 7: Operational Flowchart

    Operational Flow Chart Maintenance Operational Flow Chart Maintenance Schedule Heat Source is selected from the interior switch Overview: panel The Aqua-Hot system requires minimal maintenance if monthly, DO NOT operate the diesel burner and/or electric heating annual, and proper winterization procedures are followed element without antifreeze and water heating solution accurately.
  • Page 8: Winterizing The Aqua-Hot

    Winterization Antifreeze Types Winterization Winterizing the Aqua-Hot Antifreeze Types concentrated propylene glycol for the Aqua-Hot’s antifreeze and water heating solution. The following information addresses the necessary usage The Aqua-Hot’s domestic water heating system must be Please note that this is only necessary when mixing of a propylene glycol based “boiler”...
  • Page 9: Measuring Antifreeze Using A Refractometer

    Winterization Antifreeze Antifreeze Appendix the brand of propylene glycol antifreeze employed. Therefore, as water is an excellent heat conductor, it is Measuring Antifreeze Using a Refractometer added to the mixture. Propylene glycol antifreeze solution, mixed with distilled water, at a ratio of 35% to 50% is Rust and Anti-Corrosive Inhibitors recommended to provide the best performance combination of the aforementioned functions.
  • Page 10: General Troubleshooting

    General Troubleshooting Use and Operation Testing Functionality Use and Operation Testing Functionality General Troubleshooting Reporter Diagnosis: pumps, and heat sources until the unit has been refilled and the Reporter has been reset. 1. Check the Reporter fault screen for any fault conditions NOTE: The Reporter 2.0 (CFG 1.9 or higher) comes with associated with this unit.
  • Page 11 Testing Functionality Use and Operation Use and Operation Manual Mode RVC Network Connectivity Heating Subsystems Manual Mode All heating zones are linked together and can be run at 25%, The 2.0 Reporters with CFG 1.9 and greater come with a manual 50%, 75%, and 100% (as shown below).
  • Page 12 Service Log Service Log DATE SERVICE PERFORMED SERVICE CENTER DATE SERVICE PERFORMED SERVICE CENTER p. 20 p. 21 ©Aqua-Hot® 450D Use and Care Guide REV 220622 ©Aqua-Hot® 450D Use and Care Guide REV 220622...
  • Page 13: Warranty

    Warranty LTE-907-602 SERIES 2-YEAR LIMITED WARRANTY AQUA-HOT® HYDRONIC HEATING SYSTEM Warranty Registration Aqua-Hot Heating Systems Inc. warrants the Aqua-Hot Heater to be free from defects in Register your warranty with one of the following steps: material and workmanship under normal use and service for a period of two years on both parts and labor commencing upon the original date of registration of the vehicle.

This manual is also suitable for:

Aqua-hot reporter ahe-450-de5

Table of Contents