Explanation Of I/O Signals - Vexta CFK II Series Operating Manual

5-phase stepping motor unit
Table of Contents

Advertisement

Explanation of I/O signals

Input signals
The signal states indicate the state of the internal photocoupler (ON: power conducted;
OFF: power not conducted).
PLS input and DIR input
This driver can select either 1-pulse input mode or 2-pulse input mode as the pulse-input
mode to match the controller used. For details on how to set the pulse-input mode, see
page 29, "Pulse input modes."
1-pulse input mode (factory setting)
The controller pulses are connected to the PLS+ input (pin No.1) or the PLS- input (pin
No.2), and the rotation direction is connected to the DIR+ input (pin No.3) or DIR- input
(pin No.4).
+5 V
1. When the DIR input is "ON," a fall of the "PLS input" from "ON" to "OFF" will rotate the
motor one step in the CW direction.
2. When the DIR input is "OFF," a fall of the "PLS input" from "ON" to "OFF" will rotate the
motor one step in the CCW direction.
PLS input
DIR input
Note
• Do not allow the driver temperature to exceed 158°F (70°C), which is the heat-radiating
plate's saturation temperature during operation.
• The minimum value for the interval time when switching the rotational direction depends
on the motor's size, running speed and load moment of inertia.
20
NPN-type                PNP-type
1, 3
2, 4
PLS-
DIR-
2 µs max.
1 µs
min.
H
90 %
L
10 %
H
CCW
L
+5 V
2 µs max.
1 µs
min.
300 µs min.
PLS+
DIR+
1, 3
2, 4
CW

Advertisement

Table of Contents
loading