DELTA DORE DRIVER 610 User Manual page 2

Pilot wire programmer 1 or 2 zones
Hide thumbs Also See for DRIVER 610:

Advertisement

Prog
0h
6h
8h
17h
Turn the selector dial to PROG.
The default program is a Comfort period from 6:00 to 23:00.
1. Create your program
Programming starts on day 1 at midnight.
Press the
or
buttons to create different Economy or Comfort periods.
4
3
3
2
2
4
1
1
COMMENTS : Depending on the confi guration
made during installation, programming can be
weekly or daily. Likewise, this programming may
be done in increments of one hour, 30 minutes,
or 15minutes. To change these settings, refer to
the "installation guide", or contact our customer
service department or your installer.
Permanent mode
This mode allows you to choose a continuous
mode for each of the zone.
DRIVER 610 or 611
DRIVER 620 or 621
2
2
2
2
1
1
1
Troubleshooting
The purpose of this section is to help you quickly
solve the most common problems that you may
encounter with your product during use.
If you're unsure, or if the problem persists or isn't in
this list, contact our customer service department.
Nothing is displayed on the room unit screen.
There is no power supply.
Check your circuit breaker.
The i symbol fl ashes.
A fault has been detected in the system.
Press the button to consult the fault or faults.
The unit displays: dEF and a number.
There is a fault on the unit or the installation.
Contact your installer or our customer service
department.
23h
0h
E.g. : Comfort from 6:00 to 8:00 and from 17:00 to 23:00.
5
3
3
5
4
4
Check your program
Press the
buttonrepeatedly to check the accuracy
of the Comfort and Shutdown periods you created.
Press the OK button to check the next day.
Shutdown mode
This mode shuts down your heating system.
Turn the selector dial to
.
2
2
2
2
The unit displays ---- instead of the temperature
measured by each MINOR 500 sensor.
There is a problem on at least one of the probes.
Contact your installer or our customer service
department.
The unit is in time setting mode.
There was a mains disruption that lasted more than
2 hours.
Set the time. All other settings have remained
unchanged.
When setting the time, there is no option to set
the day.
You are in daily programming.
To switch to weekly programming, refer to the
installation guide or contact your installer or our
customer service department.
The temperature displayed does not match the
temperature measured in the room (thermome-
ter).
Refer to the installation guide or contact your
installer or our customer service department.
2. Confi rm and copy the program
Press and hold the OK button for 3 seconds to confi rm the program you created and copy it to the next day.
3. Confi rm the program
Press the OK button to confi rm and continue on to the next day to program it separately.
6
5
5
4
6
6
MINOR 500 option : set point settings
This mode is used to modify the Comfort and
Shutdown set points of each sensor.
Turn the selector dial to .
Repeat the operations for each probe.
When the last probe is set, you can set the Frost
Protection set point for all the zones.
2
To exit the mode, turn the selector dial to another
mode.
The unit displays HEAT
Your underfl oor heating or radiant ceiling heating
system is in "gradual heating" mode.
If you want to know the number of days remaining,
press the i button.
The heating elements are in Frost Protection
mode
You are in programming mode, the absence mode
or time setting mode.
Turn the selector dial to select another mode.
Pb ---- is displayed on the screen.
Problem with the connection of a heating element.
Contact your installer or our customer service
department.
7
5
6
7
7
7
You can copy the program
or
>3s
>3s
COPY
COPY
>3s
Programming zone 2)
The programming for zone 2 is available after pressing
(OK) of the day 7 of the zone 1.
COPY
Exiting the programming mode
Turn the selector dial to another mode.
1
1
8
6
Repeat actions for each
8
day of the week
8
8
on the next day
>3s
8
8
COPY
8
2
Con
2
Set point
Consigne
30
30°C
5°C
Confi rm
Validation
Vali
3
Set point
Consigne
30°C
3
5°C
Con
Confi rm
Validation
30
Set point
Consigne
Vali
15°C
5°C
Validation
Confi rm
Consig
15°