VARISCO SaxMag V Series Operating Manual

VARISCO SaxMag V Series Operating Manual

Internal gear pumps with magnetic coupling
Table of Contents

Advertisement

V-Series
Internal Gear Pumps with Magnetic Coupling
Operating Manual
Ed. 2013.03 - Rev. 00 - Code 555

Advertisement

Table of Contents
loading

Summary of Contents for VARISCO SaxMag V Series

  • Page 1 V-Series Internal Gear Pumps with Magnetic Coupling Operating Manual Ed. 2013.03 - Rev. 00 - Code 555...
  • Page 2: Declaration Of Conformity

    Declaration of Conformity in accordance with Directive 94/9/EC (ATEX) on equipment and protective systems intended for use in potentially explosive atmospheres Certificate Manufacturer: declares that when ordered as ATEX pump or ATEX pump unit, the following pumps are in conformity with Directive 94/9/EC of 23 March 1994: within the meaning of Machinery Directive 98/37/EC, Annex II A and ATEX Equipment Directive 94/9/EC, Annex X B.
  • Page 3: Table Of Contents

    OPERATING MANUAL - SAXMAG V Table of Contents: Page Declaration of Conformity General Safety Marking of instructions/notes in the Operating Manual Qualification and training of personnel Risks involved in non-compliance with safety instructions Safety-conscious work Safety instructions for the owner/operator Safety instructions for maintenance, inspection and installation work Conversion and production of spare parts by customer Improper modes of operation...
  • Page 4 OPERATING MANUAL - SAXMAG V 4.2.2 Rating plate 4.2.3 Marking pursuant to EU Directive on equipment and protective systems intended for use in potentially explosive atmospheres Main components 4.3.1 Magnetic coupling 4.3.2 Bearings 4.3.3 Materials 4.3.4 Monitoring 4.3.5 Permissible forces, torques and moments on the pump branches 4.3.6 Expected noise levels Accessories...
  • Page 5: General

    OPERATING MANUAL - SAXMAG V General This state-of-the-art Varisco pump has been manufactured with greatest care and is subject to continuous quality control. The present Operating Manual will familiarize you with the pump, its intended purpose and fields of application.
  • Page 6: Marking Of Instructions/Notes In The Operating Manual

    OPERATING MANUAL - SAXMAG V Marking of instructions/notes in the Operating Manual Safety information contained in this Operating Manual is indicated by the following symbol: General hazard symbol for areas according to ISO 7000 - 0434 Non-compliance with the safety information provided may cause hazards to persons. Warning of electric power: Safety symbol according to IEC 417 - 5036 and explosion protection:...
  • Page 7: Qualification And Training Of Personnel

    OPERATING MANUAL - SAXMAG V It is imperative to observe important information/signs directly attached to the machine such as - Sense of rotation arrow - Symbol for liquid connections - Rating plate Make sure they are kept clean and are easily legible. Qualification and training of personnel The personnel entrusted with the operation, maintenance, inspection and installation of the pump must be suitably qualified for the job.
  • Page 8: Safety Instructions For Maintenance, Inspection And Installation Work

    OPERATING MANUAL - SAXMAG V If hazardous media (e.g. explosive, toxic, hot) leak out, they must be drained off to prevent exposure of people or the environment to any risk. Relevant legal provisions must be observed. Furthermore, the magnetic field might damage data carriers and electronic components.
  • Page 9: Filling The Unit

    OPERATING MANUAL - SAXMAG V 2.9.1 Filling the unit Normally the system of suction and discharge lines and consequently the pump’s interior that is in contact with the fluid is permanently filled with the pumped medium during pump operation to prevent any potentially explosive atmosphere and the risk of dry running.
  • Page 10: Checking The Sense Of Rotation

    OPERATING MANUAL - SAXMAG V Variant 2: II 2 G Eex c Tx II 2 G: Surface unit intended for use in an area where an explosive atmosphere in the form of gases or mists is likely to occur in normal operation occasionally (EN 1127-1 Sec. 6.3) Eex c: Equipment with protection by constructional safety (prEN 13463-5) If the pump is used in a potentially explosive area, the attached temperature monitor will...
  • Page 11: Maintenance

    OPERATING MANUAL - SAXMAG V Safety information: The relevant admissible operating temperature of the pump is indicated in the data sheet. If the pump is operated at a higher temperature and no data sheet is available or the pump is used as a “pool pump”, contact the manufacturer for the maximum admissible operating temperature of the pump.
  • Page 12: Transport, Intermediate Storage

    OPERATING MANUAL - SAXMAG V Transport, intermediate storage 3.1 Transport The pump unit must be transported properly by competent personnel. Make sure that the pump or pump unit remains in a horizontal position during transport so that it will not slip out of the transport suspension points.
  • Page 13: Intermediate Storage/Preservation

    OPERATING MANUAL - SAXMAG V Intermediate storage/preservation As required, pumps should be tested and set using a liquid that also serves to protect the pump’s interior for a period of six months from the time of delivery. This liquid is a mixture of lube oil and passivating neutral detergent.
  • Page 14: Description Of The Product And Accessories

    OPERATING MANUAL - SAXMAG V Description of the product and accessories General description 4.1.1 General description of the pump V-Series internal gear pumps are volumetric rotary displacement pumps with internal gears designed to deliver fluids of any viscosity. The flow of the fluid to be delivered is produced by two gears: The directly driven rotor designed as a gear and the pinion which, also designed as a gear, engages the rotor in an off-centre configuration.
  • Page 15: Operating Principle Of The Gear Pump

    OPERATING MANUAL - SAXMAG V 4.1.2 Operating principle Arranged in a pump casing a gear pump has two gears that mesh to provide its pumping action through rotation in opposite senses. The gears are mounted on two shafts which, in turn, are supported in the pump casing and the pump cover.
  • Page 16: Rating Plate

    OPERATING MANUAL - SAXMAG V 4.2.2 Nameplate The data on the nameplate relates to a final acceptance with oil at 20° C and a viscosity of 100 cSt. 4.2.3 G C X See below Protection by constructional safety to EN 13463-5 Use in atmospheres with gas/vapour/mist Category 2 Group II...
  • Page 17: Bearings

    OPERATING MANUAL - SAXMAG V 4.3.1.1 Internal rotor The internal rotor is mounted on the pump drive shaft. The magnets are pasted on the rotor outside and hermetically sealed in to protect them from chemical attack. 4.3.1.2 External rotor The external rotor with the coupling hub is mounted on the motor shaft. The magnets sit on its inside. The magnets actually fitted are provided as a function of the torque to be transmitted by the coupling.
  • Page 18: Permissible Forces, Torques And Moments On The Pump Branches

    1,300 4.3.6 Expected noise The sound pressure level of V-Series Varisco pumps with drive, as measured at the pump height at 1 m distance from the pump, is less than 75 dB for all models. Accessories Shaft coupling: flexible coupling with / without adapter sleeve...
  • Page 19: Installation

    Damage as may have occurred: the pump unit to be installed must be in a sound condition and is required to have been stored properly (for three years max.) prior to installation. In case of doubt or if damage is found, please contact your supplier of Varisco pumps. •...
  • Page 20: Foundation

    OPERATING MANUAL - SAXMAG V Foundation The structure must be prepared such that the dimensions conform to those shown in the dimensional drawing/installation drawing. The concrete foundations shall have a sufficient concrete strength (at least Class X0) to permit safe and functional mounting according to DIN 1045 or an equivalent standard.
  • Page 21: Start-Up And Placing Out Of Service

    OPERATING MANUAL - SAXMAG V To prevent entry of foreign matter, which may result in destruction of the pump, a suction filter with a filter rating needs to be installed on the inlet side. Given its inner flow resistance, the filter rating must be sufficiently large since it affects the pump's suction capacity.
  • Page 22: Removing The Pump

    OPERATING MANUAL - SAXMAG V Removing the pump If the pump is under warranty you will need to contact Varisco prior to removing the pump. Otherwise, warranty claims will be null and void. Prior to opening the pump, make sure that: •...
  • Page 23 OPERATING MANUAL - SAXMAG V Reference to standards Potential ignition source Measures considered Trouble to be Normal expected service Hot surface EN 13463-1 Make sure that the max. permitted temperature is not exceeded! Hot surface Make sure that the rotor, the pinion and the plain bearings are EN 13463-1 properly lubricated.
  • Page 24 4. Vibration noise from relief valve 4. Increase spring pressure. Repair or renew relief valve. 1. Foreign matter in pumped fluid 1. Install filter; check materials selected. Pump experiences Contact Varisco SpA. faster-than-normal wear 2. Operating range exceeded 2. Correct pump alignment. (excessive noise development),...
  • Page 25 OPERATING MANUAL - SAXMAG V Trouble shooting Trouble Potential Causes Drive gets hot or Incorrectly designed delivery, Check the piping is overloaded delivery pressure Contact the manufacturer High containment Excessive viscosity Contact the manufacturer shell temperature Product flow for cooling Check filter and design interrupted High casing...
  • Page 26: Disassembly

    Failure to observe these instructions and/or the warning notes may result in risks to the operator and/or serious damage to the pump or pump unit. VARISCO S.p.A. shall not be held liable for any accidents or damage caused as a result of non-observance of this manual.
  • Page 27: Disassembly Of The Pump Cover

    OPERATING MANUAL - SAXMAG V Disassembly of the pump cover (04) • Remove the screws (43). Where present, use the two threaded bores to facilitate removal. When removing the cover (04) make sure that the seal (31) will not be damaged. If damaged, replace it.
  • Page 28: Disassembly Of The Pump Casing

    OPERATING MANUAL - SAXMAG V Disassembly of the pump casing (01) • Unscrew the screws (44) and pull-off the casing (01). Page 28...
  • Page 29: Disassembly Of The Plug-In Unit

    OPERATING MANUAL - SAXMAG V Disassembly of the plug-in unit • Unscrew the bolts (M3.02) and (M3.03) and pull-off the complete plug-in unit from the bearing bracket (M1.01). On principle, the plug-in unit should only be separated from the external magnet (M2.02) by radial guidance (restricted guidance).
  • Page 30 OPERATING MANUAL - SAXMAG V • Remove the bolts (M2.05) and pull-off the containment shell (M2.03) from the intermediate flange (M3.01). ! As regards the containment shell (M2.03), please remember that some remainders of the pumped fluid may still be in the pump. For safety instructions, please see the relevant media data sheet. •...
  • Page 31: Disassembly Of The Bearing Bracket

    OPERATING MANUAL - SAXMAG V Disassembly of the bearing bracket • Remove the feather key (M1.12) from the drive shaft (M1.03). • Remove the shaft sealing ring (M1.05), the slotted nut (M1.09) and the safety plate (M1.10) from the drive shaft (M1.03). •...
  • Page 32: Adjusting The Axial Play

    OPERATING MANUAL - SAXMAG V Adjusting the axial play The axial play is dependent on the viscosity and can be adjusted through various thicknesses of the cover or the casing seal. Please see the table below for further information. Pump type V50-3 V25-2 Class...
  • Page 33: Annex

    OPERATING MANUAL - SAXMAG V Annex Certificate of No Objection We, the undersigned, submit the following pump and pump accessories for repair I inspection: Type: ......... P l e a s e note: Specification: ....,..This certificate must be filled out and enclosed with any shipment for repair purposes to ensure proper handling of...
  • Page 34 Page 34...
  • Page 35 Page 35...
  • Page 36 ______________________________________________________________________________________________ VARISCO SpA Terza Strada, 9 - Z.I. Nord - 35129 PADOVA - Italy Tel. 049 82 94 111 - Fax 049 82 94 373 www.variscospa.com Vendite Italia: Tel. 049 82 94 111 - Fax 049 82 94 373 italia@variscospa.com International sales: Ph.