Download Print this page
Emerson Rosemount 214C Quick Start Manual

Emerson Rosemount 214C Quick Start Manual

Hide thumbs Also See for Rosemount 214C:

Advertisement

Quick Links

Quick Start Guide
00825-0400-2654, Rev DB
May 2021
Rosemount
214C Sensor

Advertisement

loading

Summary of Contents for Emerson Rosemount 214C

  • Page 1 Quick Start Guide 00825-0400-2654, Rev DB May 2021 ™ Rosemount 214C Sensor...
  • Page 2: Table Of Contents

    Quick Start Guide May 2021 Contents About this guide...........................3 Wiring diagram for RTDs......................5 Wiring diagram for thermocouples....................6 Additional RTD specifications....................... 7 Additional thermocouple specifications..................9 Product certifications......................... 10 Declaration of Conformity......................23 China RoHS..........................25 Emerson.com/Rosemount...
  • Page 3: About This Guide

    Be aware of the following situations: • If an I.S. approved Rosemount 214C Sensor is ordered with a housing, a transmitter enclosed in that housing may have a different I.S. approval rating. Refer to the transmitter IS certificate if applicable.
  • Page 4 Physical security is an important part of any security program and fundamental to protecting your system. Restrict physical access by unauthorized personnel to protect end users’ assets. This is true for all systems used within the facility. CAUTION Refer to Product Certification section of this Quick Start Guide documentation. Emerson.com/Rosemount...
  • Page 5: Wiring Diagram For Rtds

    May 2021 Quick Start Guide Wiring diagram for RTDs Figure 2-1: RTD Lead Wire Configuration per IEC 60751 - Single Element 3-wire 4-wire White White White Note To configure a single element, 4-wire RTD as a 3-wire system, connect only one white lead.
  • Page 6: Wiring Diagram For Thermocouples

    IEC 60584 Themocouple ASTM E230 Thermocouple Type POS (+) NEG (-) POS (+) NEG (-) Black White White Green White Yellow Brown White Blue Note Dual thermocouple sensors are shipped with one pair of the wires shrink- wrapped together. Emerson.com/Rosemount...
  • Page 7: Additional Rtd Specifications

    May 2021 Quick Start Guide Additional RTD specifications Note All specifications in this section apply to all RTDs unless noted otherwise. All RTDs meet and/or exceed type and routine tests for sensors/thermometers per IEC 60751:2008. Insulation resistance 1000 MΩ minimum insulation resistance when measured at 500 VDC at room temperature.
  • Page 8 Sensor type RT and RH: Meets 3 g vibration between 20 and 500 Hz for 150 hours. Sensor type RW: Meets 1 g vibration between 20 and 500 Hz for 150 hours. 4.10 Functional specifications Overvoltage Category I Power Environmental Pollution Degree 4 Emerson.com/Rosemount...
  • Page 9: Additional Thermocouple Specifications

    May 2021 Quick Start Guide Additional thermocouple specifications Note All specifications in this section apply to all thermocouple types unless noted otherwise. All thermocouples meet and/or exceed type and routine tests for sensors/thermometers per IEC 61515:2016. Insulation resistance 1000 MΩ minimum insulation resistance when measured at 500 VDC at room temperature.
  • Page 10: Product Certifications

    Conformity can be found at Emerson.com/Rosemount. Ordinary Location Certification The Rosemount 214C has been examined and tested to determine that the design meets the basic electrical, mechanical, and fire protection requirements by a nationally recognized test laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA).
  • Page 11 May 2021 Quick Start Guide 6.1.2 N5 USA Division 2 (NI) Certificate 70044744 Standards FM 3600:2011, FM 3611:2004, UL 50E:2007, UL 61010-1:2010, ANSI/ISA 60529:2004 Markings NI CL I, DIV 2, GP A, B, C, D; T6 (-50 °C ≤ T ≤...
  • Page 12 -50 °C for models with enclosure designation “AD1” or “SD1” 6.2.2 I1 ATEX Intrinsic Safety Certificate Baseefa16ATEX0101X Standards EN 60079-0:2012+A11:2013, EN 60079-11:2012 Markings II 1 G Ex ia IIC T5/T6 Ga (SEE CERTIFICATE FOR SCHEDULE) Thermocouples; P = 500 mW T6 -60 °C ≤ T ≤ +70 °C Emerson.com/Rosemount...
  • Page 13 May 2021 Quick Start Guide RTDs; P = 192 mW T6 -60 °C ≤ T ≤ +70 °C RTDs; P = 290 mW T6 -60 °C ≤ T ≤ +60 °C T5 -60 °C ≤ T ≤ +70 °C Special Conditions for Safe Use (X): The equipment must be installed in an enclosure which affords it a degree of ingress protection of at least IP20.
  • Page 14 -50 °C for models with enclosure designation “AD1” or “SD1”. 6.3.2 I7 IECEx Intrinsic Safety Certificate IECEx BAS 16.0077X Standards IEC 60079-0:2011, IEC 60079-11:2011 Markings Ex ia IIC T5/T6 Ga (SEE CERTIFICATE FOR SCHEDULE) Thermocouples; P = 500 mW T6 -60 °C ≤ T ≤ +70 °C Emerson.com/Rosemount...
  • Page 15 May 2021 Quick Start Guide RTDs; P = 192 mW T6 -60 °C ≤ T ≤ +70 °C RTDs; P = 290 mW T6 -60 °C ≤ T ≤ +60 °C T5 -60 °C ≤ T ≤ +70 °C Special Condition for Safe Use (X): The equipment must be installed in an enclosure which affords it a degree of ingress protection of at least IP20.
  • Page 16 1. Refer to certificate for details regarding process and ambient temperature limits. 2. When the Rosemount 214C Sensor is provided with an enclosure with a display cover, the maximum ambient shall be 95 °C. 3. The non-metallic label on the device may store an electrostatic charge and become a source of ignition in Group III atmospheres.
  • Page 17 May 2021 Quick Start Guide Special Conditions for Safe Use (X): The equipment must be installed in an enclosure which affords it a degree of ingress protection of at least IP20. China 6.5.1 E3 China Flameproof Certificate GYJ17.1010X (CCC 认证) Standards GB 3836.1-2010, GB 3836.2-2010, GB 12476.1-2013, GB 12476.5-2013 Markings...
  • Page 18 9. 产品的安装、使用和维护应同时遵守产品使用说明书、 GB3836.13-2013“爆炸性环境 第 13 部分:设备的修理、检修、修 复和改造”、GB/T3836.15-2017“爆炸性环境 第 15 部分:电气装置 的设计、选型和安装”、GB/T3836.16-2017“爆炸性环境 第 16 部 分:电气装置的检查和维护”、GB50257-2014“电气装置安装工程爆 炸和火灾危险环境电力装置施工及验收规范”和 GB15577-2007“粉 尘防爆安全规程”的有关规定。 6.5.2 I3 China Intrinsic Safety GYJ18.1024X (CCC 认证) Certificate Standards GB 3836.1-2010, GB 3836.4-2010, GB 3836.20-2010 Markings Ex ia IIC T5/T6 Ga Emerson.com/Rosemount...
  • Page 19 May 2021 Quick Start Guide 产品安全使用特殊条件 证书编号后缀“X”表明产品具有安全使用特殊条件:产品必须安装于具有 IP20 外壳防护等级的外壳内方可使用. 产品使用注意事项 1. 产品使用环境温度和温度组别的关系为: 传感器类型 最大输入功率 Pi 温度组别 使用环境温度 (mW) 热电偶 -60 ℃ ~ +70 ℃ -60 ℃ ~ +70 ℃ -60 ℃ ~ +60 ℃ -60 ℃ ~ +70 ℃ 2. 本安电气参数: 热电偶:...
  • Page 20 防爆合格证编号 644 系列 GYJ15.1502 248 系列 GYJ15.1089 4. 现场安装时,电缆引入口须选用经国家指定的防爆检验机构检验认 可、具有 Ex e ⅡC Gb 或 Ex nR ⅡC Gc 防爆等级的电缆引入装置或堵封 件,冗余电缆引入口须用堵封件有效密封。电缆引入装置或封堵件 的安装使用必须遵守其使用说明书的要求并保证外壳防护等级达到 IP54 (符合 GB4208-2008 标准要求)以上. 5. 用户不得自行更换该产品的零部件,应会同产品制造商共同解决运 行中出现的故障,以杜绝损坏现象的发生. 6. 产品的安装、使用和维护应同时遵守产品使用说明书、 GB3836.13-2013“爆炸性环境 第 13 部分:设备的修理、检修、修 复和改造”、GB3836.15-2000“爆炸性气体环境用电气设备 第 15 部 Emerson.com/Rosemount...
  • Page 21 May 2021 Quick Start Guide 分:危险场所电气安装(煤矿除外)”、GB3836.16-2006“爆炸性气 体环境用电气设备 第 16 部分:电气装置的检查和维护(煤矿除 外)”和 GB50257-2014“电气装置安装工程爆炸和火灾危险环境电 力装置施工及验收规范”的有关规定. Korea 6.6.1 EP Korea Flameproof Certificate 17-KA4BO-0305X Markings Ex d IIC T6…T1, T6 (-50 °C ≤ T ≤ +80 °C), T5 (-50 °C ≤ T ≤ +95 °C), T4…T1 (-50 °C ≤...
  • Page 22 Combination of E5 and E6 Combination of E1 and E5 Combination of E1, E5, and E6 Combination of E1, E5, E6, and E7 Combination of EM and IM Combination of N1, N5, N6, and N7 Combination of EP and IP Emerson.com/Rosemount...
  • Page 23: Declaration Of Conformity

    May 2021 Quick Start Guide Declaration of Conformity Quick Start Guide...
  • Page 24 Quick Start Guide May 2021 Emerson.com/Rosemount...
  • Page 25: China Rohs

    May 2021 Quick Start Guide China RoHS 214C 2/9/2021 214C Temperature Sensor China RoHS List of 214C Temperature Sensor Parts with China RoHS Concentration above MCVs / Hazardous Substances Hexavalent Polybrominated Polybrominated Part Name Lead Mercury Cadmium Chromium biphenyls diphenyl ethers (Pb) (Hg) (Cd)
  • Page 26 Quick Start Guide May 2021 Emerson.com/Rosemount...
  • Page 27 May 2021 Quick Start Guide Quick Start Guide...
  • Page 28 00825-0400-2654, Rev. DB May 2021 © 2021 Emerson. All rights reserved. Emerson Terms and Conditions of Sale are available upon request. The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount is a mark of one of the Emerson family of companies.