Climax VST-2735 Series User Manual

Ip/gsm+gprs alarm system

Advertisement

Quick Links

VST-2735 / VST-2745 / VST-2752
IP/GSM+GPRS Alarm System
User Manual
Mar-26-2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VST-2735 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Climax VST-2735 Series

  • Page 1 VST-2735 / VST-2745 / VST-2752 IP/GSM+GPRS Alarm System User Manual Mar-26-2020...
  • Page 2: Table Of Contents

    Table of Contents 1. Application Overview __________________________________________________ 1 1.1. Identifying the Parts ______________________________________________________ 1 1.2. Introduction _____________________________________________________________ 2 1.3. The Power Supply ________________________________________________________ 2 1.4. System Deployment ______________________________________________________ 3 1.5. How to Install the Control Panel ____________________________________________ 3 1.6. Three – Level Passwords __________________________________________________ 4 1.7.
  • Page 3 3.7. General Setting _________________________________________________________ 23 3.8. Device +/- ______________________________________________________________ 23 4. Operation ___________________________________________________________ 24 4.1. LCD Display ____________________________________________________________ 24 4.2. Entering User Menu _____________________________________________________ 24 4.3. Away Arm Mode ________________________________________________________ 24 4.4. Home Arm Mode ________________________________________________________ 25 4.5. Force Arm _____________________________________________________________ 25 4.6.
  • Page 4: Application Overview

    10. Home Arm Key 1. Application Overview — Use this key to Home Arm the system. 1.1. Identifying the Parts 11. Disarm Key — Use this key to Disarm the system. Buzzer Microphone Backlit LCD Display Green LED ON: AC Power is on. FLASH: AC Power failure.
  • Page 5: Introduction

    1.2. Introduction 1.3. The Power Supply An AC power adaptor is required to connect to VST-2735/2745/2752 series Control Panels a wall outlet. Be sure only to use an adaptor feature and/or GSM/GPRS reporting with the appropriate AC voltage rating to functions: prevent component damage.
  • Page 6: System Deployment

    the package. Use the holes on the 1.4. System Deployment plate to mark location on the wall at chest height. (Figure 4) The Control Panel is designed to be wall Step 5. Drill 2 holes into the mark location mounted, follow guidelines below...
  • Page 7: Three - Level Passwords

    Figure 4 Figure 5 named when first setting them or by editing them afterwards when resetting them.  User PIN code #1 is activated with ―1234‖ as factory default and cannot be deleted.  User PIN code #2~#10 are deactivated by factory default ...
  • Page 8: System Basic Operation

    on the first line and the system time authorization as User PIN Code, however displayed on the second line of the when a Duress Code is entered, the screen indicating the system is in Control Panel will send a silent alarm Disarm mode (Factory Default).
  • Page 9: System Configuration

    2. System Configuration Step 2. Press the learn/test button on your In order to configure the Control Panel setting, device to transmit a test code (please you need to enter the Installer Menu. To enter refer to device manual for detail). If the the Installer Menu: Control Panel receives the test code, it will display the device information...
  • Page 10  IP(SIA): IP/GPRS reporting in SIA destinations in the group fails, the format: Control Panel will retry the report group for 2 times before moving on to  IP(CID): IP/GPRS reporting in CID the next group. format.  Mail: Email reporting. (SMTP setting If the Control Panel fails to report to all required) reporting...
  • Page 11: Test Report

    reported. 2.6. GSM Setting  Alarm: Only alarm events will be The GSM function allows you to program reported. GRPS network and MMS settings, (This function is disabled for VST-2735) <NOTE> Step 1. Select GSM Setting and press OK to ...
  • Page 12: Panel Setting

    Step 2. The screen will display GSM strength P r o x y A d d r e s s in RSSI value from 1 to 9. P o r t  GSM Reset Step 2. Select APN and press OK to confirm. A P N E d i t This is for you to reset your GSM module.
  • Page 13 commands from Installers. When an installer confirm. sends a SMS command to the Control Panel, D i s a b l e the correct P-word must be entered along with Installer code for the Control Panel to recognize the command. The P-word is ―PROG” by default.
  • Page 14 reporting threshold. If the Control Panel has G S M learnt in a Temperature Sensor, it will make Step 2. Select either disable/IP/GSM and High Temperature report and raise alarm when press OK to confirm. the temperature exceeds the threshold. When the temperature drops below set value again, ...
  • Page 15: General Setting

    confirm. Confirm: When set to Confirm, If you attempt to arm when a fault exists within the system, Step 4. Select Date & Time to edit Control the arming action will be prohibited, and a Panel date and time. message will be displayed ―Fault exists! Please D a t e &...
  • Page 16  selected arm mode after the timer expires. Entry1 Time (Factory Default is 10 seconds) If a device set to Entry1 attribute is triggered when the system is armed, the Control Panel Step 1. Select Exit Time and press OK to will begin an Entry Delay countdown timer confirm.
  • Page 17: Device

    sound 2.9. Device +/- Step 1. Select Sound Setting and press OK to Devices menu allows confirm. add/change/delete all available devices. A total D o o r C h i m e of 40 devices can be included in the Control E n t r y A r m Panel.
  • Page 18   Pet Immune PIR Sensor--IRP Perimeter, Follower  External PIR - -EIR Away and Home Arm Mode:  Remote Controller --- RC  When the system is in Away and Home mode,  Carbon Monoxide --- CO ―Perimeter, Follower‖ device is ...
  • Page 19 Exit Delay: setting programmed for the user to disarm the system. (please  When the system is counting refer to 5.4. Area for detail) down Exit Delay Timer, if an  ―Interior‖ device is triggered, If the delay period expires and Control Panel will...
  • Page 20  Home Arm mode, if an ―Entry 1‖ When the system is in Home or ―Entry 2‖ device is triggered, Arm mode, if a ―Home/Delay‖ the Control Panel will start an device is triggered, the Control Entry Delay countdown timer Panel will start an Entry Delay according to Entry 1 Delay or countdown timer according to...
  • Page 21 not activated any audiable siren. <NOTE>  Please refer to Normal Open/Normal  Burglar Outdoor Close section below for further detail.  When the system is in Away and Home Arm mode, if a ―Burglar  Silent Panic Outdoor‖ device is triggered, ...
  • Page 22  C h i m e Program Siren The program siren functions allows you to Step 7. Select if you want to permanently learn in siren/bellbox and program their bypass device. Permanently behaviour. Bypass will deactivated selected device until you unselect the function. L e a r n S i r e n The Control Panel will ignore all signal...
  • Page 23: Network Setting

     Step 2. Enter a new setting, press OK to Group Control confirm. The Group Control functions allows you to  control learnt in Power Switch groups. SNTP Step 1. Select Group Control and press OK The SNTP setting is for you to enter an internet to confirm.
  • Page 24: Media Upload

    you want to specify other ports, enter the port E d i t number according to format below: D e l e t e smtp://user:password@mail server:port Step 3. If you choose to edit the setting, enter an email address, FTP address, or <NOTE>...
  • Page 25: Programming Menu

    easy recognition User PIN Code #1 is set to 3. Programming Menu 1234 by Factory Default. The programming menu is designed for user to Step 1. Select Pin Code, press OK to confirm. mange User PIN codes and other setting. to Step 2.
  • Page 26: Master Code

    E n t e r n e w c o d e confirm. Temporary Code setting is now complete..Step 3. Enter a code and press OK, you will be asked to repeat the code again. 3.6.
  • Page 27: Operation

    Step 1. The screen will display: 4. Operation S T A R T  4.1. LCD Display Step 2. Press Down key to scroll through the The Control Panel’s LCD will display the fault events. When all fault events are system information according to different status displayed, the screen will show: and panel modes.
  • Page 28: Home Arm Mode

    User PIN code and press the Away Step 1: Arm key on the Remote Keypad.  Select Home Arm under User Menu (Please refer to Remote Keypad and press OK. manual for detail)  When under Disarm mode, enter a ...
  • Page 29: Disarm

    below to Forced Arm the Control Panel. sensor and press OK again. + D C Z 0 1 Step 1: When fault events are displayed, Z 0 2 repeat the same arming action again The bypassed condition of a sensor will be Step 2: The Control Panel will begin Exit Delay remove automatically after the panel is armed, Timer countdown according to the...
  • Page 30: Keypad Lockdown

    number. The screen will display ―ALARM! the alarm will be activated ALARM!‖ to notify the user. 4.10. Keypad Lockdown  Stopping the Alarm The Control Panel features Keypad Lockdown Step 1: To Stop the alarm, disarm the Control function to prevent continuous User PIN Code Panel, please refer to 4.5.
  • Page 31: Fault Display

     3. Alarm event: The panel will play the alarm GSM-Related Failure message according to alarm type which  Network failure includes: Burglar, Fire, Medical Emergency  When a fault event exists in system , the Fault LED will light up. To ensure the call is successfully received by the recipient, the recipient should acknowledge the message by pressing the appropriate...
  • Page 32: Vesta Ez Home Application

     Panel Selection 5. Vesta EZ Home Upon starting the application, you will first enter Application Panel Selection menu Vesta Home Application smartphone application designed to assist you in sending SMS Command The intuitive and simple interface help you communicate with Control Panel by SMS message easily.
  • Page 33   Enter the panel information, including the You will return to Panel Selection menu, panel name you want to use in the the new panel you entered will be application, panel SIM card number, a User displayed, select the panel to proceed to PIN Code and the SMS keyword used to edit SMS commands for the panel.
  • Page 34  Panel Main Menu <IMPORTANT NOTE> The Panel Main Menu is displayed as follows:  The default setting in the application may be different from the setting in your Control Panel. When you use the application to program the system for the first time, please check both application and Control Panel settings for discrepancies.
  • Page 35  Away Arm / Home Arm / Disarm To change system mode, select the icon for Arm / Home / Disarm respectively. A SMS message edit screen will appear for you to confirm. Press ―Send‖ to send the SMS command to panel. ...
  • Page 36  Alarm Setting message edit screen will appear for you to confirm. Press ―Send‖ to send the SMS The Alarm Setting Menu allows you to edit command to panel. alarm related configuration.  Reporting Setting The Report Setting Menu allows you to edit your telephone numbers for reporting.
  • Page 37 SMS(CID)/ SMS(Text)/ GSM CID/ Voice Edit Device reporting options are available.  The Edit Device option allows you to edit a  Press ―Save‖. A SMS message edit screen device name, and attribute for Door will appear for you to confirm. Press Contact, PIR and EIR Sensor.
  • Page 38 Siren Control PSS Control   The Siren Control option allows you to The PSS Control option allows you to turn change Siren settings. on/off your Power Switch groups.   Select the function you want to edit and Select the Power Switch group you want to choose to enable or disable the function.
  • Page 39 Capture Image  Home Automation Rules  You can manually request your PIR Set Home Automation rules. Camera, PIR Video Camera or IP Camera to take a picture or video. The picture will be sent to the destination programmed under Media Upload section. ...
  • Page 40: For Android Phone

    ―Send‖ to send the SMS command to 5.2. For Android Phone panel. The Android version of Vesta EZ Home Application supports complete SMS command <NOTE> functions, including the commands to inquire  system mode change (Arm, Control Panel setting and update appllication Home, Disarm), the Power Switch data with latest setting information.
  • Page 41  Panel Selection Upon starting the application, you will first enter Panel Selection menu  You will return to Panel Selection menu, the new panel you entered will be displayed, select the panel to proceed to edit SMS commands for the panel. ...
  • Page 42 <IMPORTANT NOTE>  Whenever send command, please make sure you receive confirmation message from Control Panel before  Edit Panel Information proceeding send next command. If you receive an error You can edit the Control Panel information by message from the Control Panel, pressing ―Edit‖...
  • Page 43  Sync with Panel  PIN Setting Press the Menu button on you Android phone The PIN Setting Menu allows you to edit User to bring up the ―Sync‖ option. Press ―Sync‖ to PIN Codes and SMS Keyword. send an SMS command to Control Panel requesting it to report back its current mode.
  • Page 44  Alarm Setting <NOTE>  The Alarm Setting Menu allows you to edit You can delete the User PIN code by alarm related configuration. keeping the Pin Code field blank and save the setting. User PIN Code 1 cannot be deleted.‖ <IMPORTANT NOTE>...
  • Page 45 options and choose to sync either the configurations or high/low temperature setting.  Enter the telephone number for reporting, and select report type and events. Only SMS(CID)/ SMS(Text)/ GSM CID/ Voice reporting options are available.  Press ―Save‖. The phone will send a SMS ...
  • Page 46  You can press the ―Menu‖ button on your  Device Setting Android phone to bring up the ―Sync‖ The Device Setting Menu allows you to edit options choose sync either device, control Siren, PSS, and request PIR Reporting 1~3 or 4~6. Camera image.
  • Page 47  Edit Device You can press the ―Menu‖ button on your Android phone to bring up the ―Sync‖  The Edit Device option allows you to edit a options choose sync device device name, and attribute for Door information in different zones. Contact, PIR and EIR Sensor.
  • Page 48 Siren Control PSS Control   The Siren Control option allows you to The PSS Control option allows you to turn change Siren settings. on/off your Power Switch.   Select the attribute and choose to enable Select the Power Switch group you want to or disable the function.
  • Page 49 Capture Image  Home Automation Rules  You can manually request your PIR Set Home Automation rules. Camera, PIR Video Camera or IP Camera to take a picture or video. The picture will be sent to the destination programmed under Media Upload section. ...
  • Page 50  Press ―Save‖. A SMS message edit screen will appear for you to confirm. The phone will send a SMS command to panel. <NOTE>  system mode change (Arm, Home, Disarm), the Power Switch group selection is limited to #1 only. ...
  • Page 51: Appendix

    6. Appendix 6.1. Fault Event Description During operation, when the panel detects faulty events, the panel will log the event and make reports. When fault events exist in the system, the panel Fault LED will light up and the panel will emit a beep every 30 seconds.
  • Page 52: Sms Remote Command

    6.2. SMS Remote Command VST-2745 and VST-2752 can be controlled remotely by SMS Commands for arm/home/disarm action and setting configuration. Please refer to following information for details.  SMS Command Composition A SMS command is composed of the following items: Command: The action itself, the command is always followed by a colon ―:‖...
  • Page 53  SMS Command Table Command Comment Example & Descriptions ECHO Send SMS Example => ECHO: Test panel Send SMS Example => USRS:1,1,1234,user,1 Parameter 1: Enter 1 Parameter 2: User ID 1~10 = User PIN Code# 95 = Guard Code Change user 96 = Master Code USRS...
  • Page 54 10 = 24 Hours 11 = Fire 12 = Medical Emergency 13 = Water 14 = Set/Unset 15 = Silent Panic 16 = Personal Attack 17 = Trigger Scene 18 = Silent Burglar 19 = Entry2 Parameter 8: PSS groups in bitwise hex string, BIT1 to BIT8 for Group 1~8, keep blank for non-PSS devices.
  • Page 55 7 = Paris 8 = Istanbul 9 = Moscow 10 = Taipei 11 = Tokyo 12 = Sydney 13 = Auckland 14 = Adelaide 15 = Brisbane 16 = Darwin Send SMS Example => REST:5 REST Reboot panel Parameter 1: Delay time in second (1~5) Send SMS Example =>...
  • Page 56 Send SMS Example => XMPP:xmpp://user:password@192.168.0.190:5222,domain,admin,40 Change Parameter 1: XMPP server URL XMPP XMPP setting Parameter 2: XMPP server domain Parameter 3: Buddy list Parameter 4: Ping interval in seconds (10~60) Send SMS Example => GAPN:internet,, Change Parameter 1: GPRS APN GAPN GPRS Parameter 2: GPRS user name...
  • Page 57: Control Panel Mode And Response Table

    6.3. Control Panel Mode and Response Table For Alarm Activation by Events and Control Panel Responses, please refer to the following table: System Mode / Status Attribute Under Under Exit Under Home Disarm Mode Away Mode Home Mode Away Entry Timer Entry Timer Timer...
  • Page 58 Instant Fire Instant Fire Instant Fire Instant Fire Instant Fire Instant Fire Fire Alarm Alarm Alarm Alarm Alarm Alarm Instant Instant Instant Instant Instant Water Instant Water Water Water Water Water Water Alarm Alarm Alarm Alarm Alarm Alarm Instant Instant Instant Instant Instant...
  • Page 59: Event Code

    6.4. Event Code  133 – 24 Hours  100 – Medical  When a device set as 24 Hour is  101 – Personal emergency triggered.  When Wrist Transmitter  136 – Burglar Outdoor Emergency Pendant (WTR)  When a Burglar Outdoor Alarm is pressed.
  • Page 60 loses the AC power connection.  383 – Device Tamper  When a device’s tamper switch is triggered.  384 – Device Low Battery  When a device’s is under low battery.  389 – Self Test Failure  – Arm/Disarm Remote Controller)

This manual is also suitable for: