Advertisement

Quick Links

Sep. 9, 2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CTC-1052-QT and is the answer not in the manual?

Questions and answers

Summary of Contents for Climax CTC-1052-QT

  • Page 1 Sep. 9, 2020...
  • Page 2: Table Of Contents

    4.2.2. Dial in Twice (Ring Count Disable) ......................6 4.3. Programming Your 1052-QT ________________________________________________6 4.4. SMS Remote Programming ________________________________________________20 4.4.1 CTC-1052-QT SMS Remote Programming Command Table ................ 20 4.5 PC Programming Mode ____________________________________________________26 4.5.1 Function Tabs ..............................28 4.5.2 Profile ................................. 37 5.
  • Page 3 5.3.2. In Walk Test Mode ............................48 5.3.3. In Idle Mode ..............................48 5.4 Global Test ______________________________________________________________49 5.5 Factory Reset ____________________________________________________________49 6. Appendix ............................50 6.1. CID Event Code __________________________________________________________50 6.2. CTC-1052-QT Programming Command Table _________________________________52 6.3. CTC-1052-QT Voice Prompts _______________________________________________54...
  • Page 5: Application Overview

    LED will turn mobility timer and send test report steady on. (see command 44). 10. 4G/LTE Fault Indicator (Yellow) — Before CTC-1052-QT dials out for — FLASH every 5 seconds: SIM card alarm reporting, press once to cancel missing the alarm reporting —...
  • Page 6: The Power Supply

    Local Programming to fully charge the battery. (optional).  After power is supplied to CTC-1052-QT, — A PC programming cable (QT Cable slide the power switch to ON position to C) is provided to connect CTC-1052- power on the Control Panel.
  • Page 7: How To Install The Control Panel

    Hook the Control unit onto the Wall Mounting Bracket (holding the unit with the front facing you). 1.5. Compatible with Climax’s SMS Editor CTC-1052-QT is compatible with Climax‟s SMS Editor, which is designed to facilitate SMS remote programming via a PC. This tool allows...
  • Page 8: Learn-In The Devices

    Button right after the double beep learnt-in sensors will be assigned to zone 1-20 and the voice prompt. sequentially. 2. CTC-1052-QT will enter learning mode as it plays the voice prompt “Ready to learn 2.1. Command Learning sensor, Press sensor button”. The Red LED...
  • Page 9: Remove The Devices

    Device for detailed instructions. Step 3. Enter default ACCESS CODE, 1111 followed by #. 3.2. Local Removing Step 4. CTC-1052-QT will emit 2 short beeps  and the red LED starts to flash, Under Local Learning Mode, the devices indicating it is in Programming Mode.
  • Page 10: Remote Programming Mode

     How to enter Commands? is set as factory default). Please make sure CTC-1052-QT Step 1. Dial CTC-1052-QT and wait for CTC- Programming Mode (RED flashes 1052-QT to answer. continuously) before trying any CTC-1052- Step 2. Enter 1111 (default 4-digit Access QT Command Functions.
  • Page 11 Step 5. Enter (#) to terminate the Command  Example: 201*27912518# Operation.  201 represents it being the 1 Step 6. CTC-1052-QT will emit a short beep, Caller ID. indicating successful programming.  27912518 represents the Caller ID The maximum interval between key strokes is 2 Step 3: A short beep will be heart via the minutes.
  • Page 12  If you hear CTC-1052-QT emit one beep Available Key-in options: instead, that means the programming of the telephone number has failed. Please Tel. Number / Function Selection repeat the programming steps again. Sequence IP Address  Likewise, the 2 or 4 Tel.
  • Page 13 Method command #5 and/or #6.  <NOTE> When multiple Tel. numbers selected, CTC-1052-QT will always dial  The latest Command (20-24) setting(s) in respective programmed order. will overwrite any previously entered  setting(s). The latest Command (05-06) setting(s) will overwrite any previously enter ...
  • Page 14 If Help Arrived Signaling is set to OFF,  If the function is set to ON, you can answer CTC-1052-QT will return to idle mode when the incoming call by pressing the Active Alarm Reporting is completed. button of WTR, PB, or Fall Sensor, or the Red Help Button on CTC-1052-QT.
  • Page 15 The Red Help Button can be enabled or disabled to send an Emergency alarm AC Fault Report report:  The CTC-1052-QT can be programmed to Function Selection Result send a Fault Report when an AC power failure is detected. Function Selection...
  • Page 16 Auto Answer for Remote Programming automatically enter the Follow-On mode as  CTC-1052-QT can be programmed to auto specified by Command (45). answer incoming phone calls after a pre-set Once Follow-On Mode is terminated, CTC- number of rings have been reached. The...
  • Page 17  This will disable or enable the Inactivity Timer  It is used to select the Follow-On Choice for with selectable count down periods. Options CTC-1052-QT after it has made a report to are: the Monitoring Center.  Function Selection...
  • Page 18 Speech mode is 5 minutes. During the 5- Function Selection Result minute period, CTC-1052-QT will emit two WAIT COMMAND beeps via the telephone handset to alert the call recipient the remaining time of 20 & LISTEN 10 seconds. Press any DTMF key except...
  • Page 19 SIM card PIN Function code. Result Selection  If the SIM card PIN code is not required, CTC-1052-QT can receive calls normally English regardless of the settings of Commands 61 and 62. French  Please set the SIM card PIN code correctly...
  • Page 20 (2) for Two-Way mode. Time Delay time for fall sensor.  Please refer to programming command  CTC-1052-QT can be programmed to delay table section for configuration. alarm reporting triggered by a fall detection from (00) (instant reporting) to (99) seconds.
  • Page 21 If help has not arrived after sending the Speech Report ACK alarm report for 4 times, CTC-1052-QT will  A two-way communication is established dial the telephone number programmed by when a call is made from CTC-1052-QT to Command open two-way...
  • Page 22 CTC-1052-QT will emit a long successful. beep and automatically returns to Programming mode.  Factory default is (0), Any DTMF. Step 3: CTC-1052-QT will emit 2 beeps to Function Selection Result indicate that Silent Pendant is learnt- in successfully. Any DTMF ...
  • Page 23 If no signal is received within 20 CTC-1052-QT exits the Programming Mode sec, CTC-1052-QT will emit a long and returns to idle mode. beep and automatically returns to Programming mode. Step 3: CTC-1052-QT will emit 2 beeps to indicate device learnt-in successfully. ...
  • Page 24: Sms Remote Programming

    Step 7: Editing is complete; you may send to the Remote Programming Control Panel. Command Table. <EXAMPLE> 4.4.1 CTC-1052-QT SMS Remote Programming Command Table  If the SMS Keyword is set as PROG, and Access Code is set as 1111 (factory default). CORRESPON- DING DTMF COMMAND EXAMPLE &...
  • Page 25 CORRESPON- DING DTMF COMMAND EXAMPLE & USAGE ITEM DEFAULT CHARACTER COMMANDS Global PROG 1111 ACNTG:1234, To set/change the same 4- 6- 8- account ACNTG digit account number for all 4 telephone numbers (Null=to account number clear 4 Telephone numbers) number PROG 1111 ACNT1:1234, To set/change the 4- 6- 8-digit Account ACNT1...
  • Page 26 CORRESPON- DING DTMF COMMAND EXAMPLE & USAGE ITEM DEFAULT CHARACTER COMMANDS PROG 1111 GUDTI:10 Guard time To set the guard time delay time for a compatible sensor GUDTI delay (except Fall Sensor) 00=Instant, 01-99=1-99 seconds PROG 1111 TESTC:0 Periodic test To set the periodic test call TESTC 0 = Off...
  • Page 27 CORRESPON- DING DTMF COMMAND EXAMPLE & USAGE ITEM DEFAULT CHARACTER COMMANDS PROG 1111 REPLA:886&0 Country No country REPLA To replace the Country Code with 0 code code 886  Country Code PROG 1111 TCIP1:192.168.1.110 No IP IP address TCIP1 To set/change the IP address for the Monitoring Station address Input IP address: 000.000.000.000 to 255.255.255.255 PROG 1111 TCIP2:192.168.1.110...
  • Page 28 2. GPRS functions can only be programed via SMS messages, and the commands MUST be sent in this sequence: Country code  IP address  Port number  GPRS/IP account number  Access Point Name  User name  Password. 3.
  • Page 29 SMS Command:PROG1111 PRTCL:01005 GROUP Index Voice Prompt ON OFF Value Total Value 1+0+4+0+0+0+0+0 = 005 (YYY) Example 2 - “Inactivity timer expiring, please reset” (set as Index 3). - “Inactivity timer reset” (set as Index 4). SMS Command:PROG 1111 PRTCL:01012 GROUP Index Voice Prompt ON OFF...
  • Page 30: Pc Programming Mode

    The 1052-QT-Tool programming software Step 4. After installing the USB driver, you can start programming with 1052-QT-Tool programming software via USB port. To download 1052-QT-Tool programming software, open your browser and type below URL in the address bar: https://www.climax.com.tw/climax-download-1052qt.html...
  • Page 31 Step 5. 1052-QT-Tool is a portable application and requires no installation. Simply unzip the file to a desired folder and double-click “1052-QT-Tool” to execute the programming tool. The following configuration screen will be opened. Step 6. Select the COM port generated for 1052-QT after installing the USB Driver (the USB port connected to 1052-QT), enter the password (default 1111), and then click “Open”.
  • Page 32: Function Tabs

    A “Read All command success!” message will pop up. Click “OK”, and the current 1052- Step 7. QT settings will be displayed. 4.5.1 Function Tabs To program the 1052-QT Control Panel, click on different function tabs to see and edit 1052-QT functions.
  • Page 33 CID. 05# To select the number for alarm report: - Select which telephone number (1-4) & GPRS (1-2) is/are to be used for Alarm Reporting. 06# To select the number for status report: - Select which telephone number (1-4) & GPRS (1-2) is/are to be used for Status Reporting. 4.5.1.2 IP Report The “IP Report”...
  • Page 34 01# -04# Telephone Number Programming (01-04) - Used to program the 1 Tel. numbers respectively. - When entering the phone number, entering () represent a 3-sec. pause. (e.g. Switchboard system, extension, etc.) - Up to 20 digits including () are allowed for each telephone number. 11# -14# Account Number Programming (01-04): - Set the account numbers for the 1 Tel.
  • Page 35 37# AC Fault Report: - When set to ON, CTC-1052-QT will send a Fault Report after a continuous one hour of AC Fault condition is detected. - When set to OFF, CTC-1052-QT will not send an AC fault report.
  • Page 36 Delay Time for Fall Sensor, instead of Command #42 Guard Time Delay. 43# Periodic Test Call: - CTC-1052-QT can be programmed to make test calls periodically from every 1 – 7 or 30 days. Whenever programming mode is accessed, CTC-1052-QT will reset the Periodic Test Call timer.
  • Page 37 67# Setting the Help Arrived Timer: - This is used to set the countdown timer for CTC-1052-QT to resend the alarm report if no help has arrived after the initial report is made (meaning the reset button has not been pressed before the timer expires).
  • Page 38 The Device tab allows user to learn in or remove devices from CTC-1052-QT. 93# Learn-In Silent Device: This is used for learning in silent devices. When CTC-1052-QT receives the alarm signal from a Silent Device, it will not sound any warning beeps during Reporting and Guard time period.
  • Page 39 <NOTE>  Learning can only be completed within the signal reception range of CTC-1052-QT. If no signal is received within 20 sec, a “Learning Fail” message will pop up, and CTC-1052-QT will automatically return to Programming mode.  Adding a Device for a second time is prohibited unless it is removed from the system first.
  • Page 40 Click “Remove” to remove all devices from CTC-1052-QT. A message “Remove All Device command success!” will pop up. 81# Remove Zone 1 Device Click “Remove” to remove zone 1 device from CTC-1052-QT. A message “Remove Zone 1 Device command success!” will pop up. 82# Remove Zone 2 Device Click “Remove”...
  • Page 41: Profile

    - When an incoming call matches with any of the programmed Caller ID(s), CTC-1052-QT will auto-answer the call without checking access code or any button press. - CTC-1052-QT will match the numbers starting from the last digit, and verify 10 digits at the most.
  • Page 42 If you select a different profile from the drop down menu, the “Current Setting” profile will disappear to indicate the 1052-QT-Tool is no longer displaying CTC-1052-QT‟s current configuration. To access Current Setting again, click on “Read”. Default When “Default” is selected, the 1052-QT-Tool will display default configurations of CTC-1052-QT, you can use this profile to return CTC-1052-QT to its default setting.
  • Page 43 Profile Manager Click on “Profile Manager” to manage the profiles: Delete Profile Select a profile and click on “Delete Profile”. A pop-up window will ask you to confirm the selection: Select “Yes” to delete the profile, or “No” to return to the previous page. Profile Backup &...
  • Page 45: Operation

    Answer Numbers. If a user calls the Control Panel using an auto-answer number, the Control When the system is in Idle Mode, CTC-1052-QT Panel will pick up the call and instantly open up is ready to execute the following functions: a two-way communication with the caller.
  • Page 46: Devices Low Battery

    Monitoring Center and the GREEN timer was still not reset, when reaching next LED returns to steady ON. pre-set time, the CTC-1052-QT will emit a 5.1.5. Devices Low Battery beep every 5 minutes to notify the user for 30 minutes.
  • Page 47: Alarm Activation

    With the phone number 0987654321, the format will be heard once the CTC-1052-QT goes should either INCLUDE or EXCLUDE Contry off-hook. Code, which is “886” for Taiwan as below: Guard Time Delay INCLUDE +886987654321  Guard Time Delay time is a time period...
  • Page 48: Gprs Reporting Method

    Please inquire your  After a successful report, CTC-1052-QT will service provider for your GPRS username. then follow the choice of Command #38, to If no username is required, you may skip enter Follow-On and/or Call-Back mode. this step.
  • Page 49 1052-QT as many times as possible 20 & 10 seconds before the Follow-On until Help Arrived Mode is terminated period expires, CTC-1052-QT will emit two (Please refer to Help Arrived Signaling beeps to alert both the user and the section for more details).
  • Page 50: Help Arrived Mode

    1052-QT will dial the telephone  After sending the alarm report for 4 number programmed times and that the Test/Reset Button Command 75. When answered, is still not pressed, CTC-1052-QT will a Two-way communication is dial telephone number established. call...
  • Page 51: Speech Reporting Method

    If Speech Reporting Method is selected, Control Panel will report after dialing, CTC-1052-QT will open a two- sequentially according to the following way voice communication between the Call report sequence: GPRS #1, GPRS #2, Tel. Recipient and CTC-1052-QT for 1-10 #1, Tel.
  • Page 52: Walk Test (Range Test)

    If new event happens, CTC-1052-QT  prompt. starts the reporting immediately. Step 2. CTC-1052-QT is now in learning mode The control panel will not stop reporting and the Red LED will start flashing. until receiving at least 1 successful report from each report methods Step 3.
  • Page 53: Global Test

    TEST button again to observe the range for its operation. Step 3. If CTC-1052-QT responds with one long beep, then the particular device is within the operation range. Step 4. Please wait for at least 30 seconds...
  • Page 54: Appendix

     147 - Sensor Supervisory Failure ACCT MT QXYZ GG C  When CTC-1052-QT is unable to receive the signal transmitted from the Wrist Transmitter for a pre-set period by And is explained in the following table: Command #49, the Green LED will flash every 2 seconds.
  • Page 55 CTC-1052-QT will send FCC Statement this event code with the event qualifier Q “1” every 15 minutes for four times.
  • Page 56: Ctc-1052-Qt Programming Command Table

    6.2. CTC-1052-QT Programming Command Table TERM DTMF DTMF DTMF COMMAND OPERATION CHARACTER DEFAULT NATO COMMANDS To Set Caller ID (201-220) Enter: Caller ID Sequence + * + Caller ID Note: Caller ID Sequence: 201-220 Symbol: * Null Caller ID: maximum 20 digits...
  • Page 57 DTMF DTMF TERMI- DTMF COMMAND OPERATION CHARACTER DEFAULT NATOR COMMANDS Test call, 0 = OFF, 1 = 1 Day, 2 = 2 Days, 3 = 3 Days, 4 = 4 Days. 5 = 5 Days, No test call 6 = 6 Days, 7 = 7 Days, 8 = 30 days Mobility time Mobility time 00= Disable, 01 - 36= 1 - 36 Hours...
  • Page 58: Ctc-1052-Qt Voice Prompts

    6.3. CTC-1052-QT Voice Prompts The Control Panel plays voice prompts on important occasions to report its condition or remind you to take a specific action. Information on voice prompts is provided in the chart below. Voice Prompt Condition Played once after long pressing (6 seconds) the Multi-function Button Release the Button on the Control Panel to enter learning mode.

Table of Contents