Climax CTC-1052 User Manual

Climax CTC-1052 User Manual

Senior care series medical alarm system

Advertisement

+--E1
19-Dec-2012

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CTC-1052 and is the answer not in the manual?

Questions and answers

Summary of Contents for Climax CTC-1052

  • Page 1 +--E1 19-Dec-2012...
  • Page 2: Table Of Contents

    1.3. Insert GPRS/3G SIM Card ________________________________________________________ 3   1.4. How to install the Control Panel __________________________________________________ 3   1.5. Compatible with Climax’s SMS Editor ____________________________________________ 3 2. Learn-in the Devices ________________________________________________________ 4    2.1. Learning Pendant #1 ____________________________________________________________ 4  ...
  • Page 3 5. Appendix __________________________________________________________________ 27    5.1. CID Event Code ________________________________________________________________ 27   5.2. Tunstall Event Code____________________________________________________________ 28   5.3. Scancom Event Code __________________________________________________________ 29   5.4. CTC-1052 Programming Command Table ________________________________________ 31   5.5. CTC-1052 SMS Remote Programming Command Table ___________________________ 33...
  • Page 4: Application Overview

    — Press once in normal mode to reset indicates no 3G connection/signal. mobility timer (see command 44) 10. GPRS/3G Fault Indicator (Yellow) — Before CTC-1052 dials out for alarm — FLASH every 5 seconds: SIM card reporting, press once to cancel the missing alarm reporting —...
  • Page 5: The Power Supply

    Unit Input power CTC-1052. — A special telephone cord to connect In addition to the adapter, there is a CTC-1052 and your phone unit for rechargeable battery inside CTC-1052, Local Programming (optional). which serves as a back-up in case of a power failure.
  • Page 6: Insert Gprs/3G Sim Card

    The Control Panel can be mounted on the wall SIM Card will delete its SMS message or wherever desired (e.g. on the table). Ensure whenever the CTC-1052 is powered on. the Control Panel is fitted at approximately chest height where the buttons, microphone,...
  • Page 7: Learn-In The Devices

    3 sec., then a double beep when it reaches 6 sec. 1. Users can enable CTC-1052 to get into the learning mode to learn in WTR- Series, Step 3. Release the button after you heard the or Fall Sensor.
  • Page 8: Learning Pendant #2

    6 seconds (once pressed, a button Step 2. Once pressed, a button beep sound beep sound will be heard. CTC-1052 will be heard. CTC-1052 will emit one will emit one short beep at 3 sec., then short beep at 3 sec., then a double a long beep when it reaches 6 sec.)
  • Page 9: System Configuration

    Step 3. Enter default ACCESS CODE, 1111 section System Configuration, Entering followed by #. Programming Mode. Step 4. CTC-1052 will emit 2 short beeps and the red LED starts to flash, indicating Follow the protocol below to command it is in Programming Mode.
  • Page 10 Step 4. Enter the desired Command function number. Step 5. Enter (#) to terminate the Command Command 05-06 Operation. Select Telephone Number for Alarm Step 6. CTC-1052 will emit a short beep, Reporting and Status Reporting indicating successful programming. < > <...
  • Page 11 (12) in command #5 and/or #6. When multiple Tel. numbers & 3 Tel. #s (13) selected, CTC-1052 will always dial in respective programmed order. & 4 Tel. #s (14) The latest Command (05-06) setting(s) Tel & 5 GPRS. #s (15) will overwrite any previously enter setting(s).
  • Page 12 Digital Reporting. If Speech Method is selected: Command (10): Set the same account number for all telephone numbers. After the dialing for alarm/emergency trigger is successful, CTC-1052 opens Command (11-14): account numbers for the 1 Tel. numbers used...
  • Page 13 The fault situation includes Low Battery Fault (for both CTC-1052 and Devices) Command 31 and AC Failure. Ringer Enable for Incoming Calls CTC-1052 can be programmed to emit a Command 33 ring tone as an audio alert, or silent for incoming calls. Help Arrived Signaling...
  • Page 14 #24 is set as (0), (1) or (2)) Command 35 Function Selection Result Silent Mode Follow-On CTC-1052 can be selected to operate in Call-Back Silent Mode. This will mute all normal operation warning beeps, guard time Follow-On & Call-Back tone, key tone and ring.
  • Page 15 Monitoring Center. (fall detection). < > < > CTC-1052 can be programmed to delay alarm reporting from (00) (instant reporting) When the Monitoring Center calls back to (99) seconds. within this 5-minute period, CTC-1052 auto-answers the call after the 1...
  • Page 16 Command #38 set as (0) or Timer with selectable count down periods. (2). Options are: It is used to select the Follow-On Choice for CTC-1052 after it has made a report to Function Result the Monitoring Center. Selection...
  • Page 17 This option is used to enable system Speech mode is two mins. During the 2- Supervision function. Once enabled, CTC- min period, CTC-1052 will emit two beeps 1052 will be able to receive the check-in via the telephone handset to alert the call signals from Wrist Pendants (WTR-) to recipient the remaining time of 20 &...
  • Page 18 < > < > 6 Days 7 Days Whenever a SIM Card PIN code is entered, the system will check if the 8 Days entered PIN code is matched. If not, 9 Days the SIM card will be locked. 10 Days This function is not used to change SIM Card PIN Code.
  • Page 19 Factory default is Command 80-84 set as (3). Remove Devices Please refer to programming command table section for configuration. CTC-1052 can be programmed to remove ALL previously learnt devices by entering < > < > (80) followed by (#). The system will emit...
  • Page 20 Programming mode. Step 2: Press the Pendant Button within 20 Step 3: CTC-1052 will emit 2 beeps to secs. indicate that Pendant #2 is learnt-in successfully. Learning can only be completed...
  • Page 21 CTC-1052 will emit a long beep and automatically returns to Enter (99) and (#), after one short beep, Programming mode. CTC-1052 exits the Programming Mode and returns to idle mode. Step 3: CTC-1052 will emit 2 beeps to indicate the device is learnt-in...
  • Page 22: Sms Remote Programming

    4.1. Idle Mode < > < > When the system is in Idle Mode, CTC-1052 is ready to execute the following functions: Prior to procced, please be reminded to change the language setting of your mobile phone to English. 4.1.1. Answering Incoming Phone Calls Step 1: Use your handset and go into the SMS edit screen.
  • Page 23: Non-Emergency Speech Call

    CTC-1052 dials the be retried. phone number entered in Command Step 3. At the last 20 & 10 secs, CTC-1052 will emit a beep via the telephone Step 3. If the dialing succeeds, CTC-1052 will handset to alert the call recipient.
  • Page 24: Ctc-1052 Battery Disconnection

    After the battery is restored and it lasts for not be reset, when reaching next pre-set 10~15min, CTC-1052 will send Battery time, the CTC-1052 will emit a beep at Restore report to Monitoring Center and every 5 minutes to notify the user for 30 the GREEN LED returns to steady ON.
  • Page 25: No Pendant Present

    INCLUDE or EXCLUDE press & hold the Reset Button for 16 Contry Code, which is “886” for Taiwan as seconds. below: Step 2: During the 16-sec period, CTC-1052 INCLUDE +886987654321 will emit one short beep a double...
  • Page 26 Once the first reporting succeeded, successfully received and CTC-1052 is in progress of back- Monitoring Center, CTC-1052 will then up reporting, the confirmation beeps follow the choice of Command #38, to will not be heard. enter Follow-On and/or Call-Back mode.
  • Page 27 Enter (7) to Speaker Volume Control and then press (6) or (4) to increase During the Follow-On period, the Monitoring and decrease the levels of speaker Center can remotely control CTC-1052 by the volume “Two-Way” DTMF commands below: communication modes.
  • Page 28 DTMF keys over 1 second to enable the function you desire. CTC-1052 will then enter the 15 mins waiting period again. If RESET If the levels of speaker volume and button is still not pressed, CTC-1052...
  • Page 29: Walk Test (Range Test)

    If both Digital and Speech Alarm its operation. reporting are set, the reporting call Step 5. If CTC-1052 responds with one long sequence will only be terminated beep, then the particular device is once one Digital reporting (any of CID, within the operation range.
  • Page 30: Factory Reset

    Step 2. Within 5 secs, press Pendant 5. Appendix button. 5.1. CID Event Code Step 3. CTC-1052 will emit a short beep and report to Monitoring Center. 100 - Panel emergency When Red HELP button is pressed. 101 - Personal emergency 4.5 Factory Reset...
  • Page 31: Tunstall Event Code

    When Smoke Detector is under Low Battery Status, the Green LED flashes D#1013 - Sensor Supervisory Failure every 2 sec with 3 short beeps every When CTC-1052 is unable to receive hour. the signal transmitted from the Wrist 380 - WTR Low Battery Transmitter for a pre-set period by Command #49.
  • Page 32: Scancom Event Code

    30 secs. sec with 2 short beeps every hour. D#1019 – Panel Low Battery / Panel When CTC-1052 is under Battery Not Battery Disconnection Connected status, the Green LED flashes every 2 sec with 2 short beeps When CTC-1052 is under Low Battery every hour.
  • Page 33 triggered or Smoke Detector’s test button is pressed. When Carbon Monoxide Detector (CO) is triggered or Carbon Monoxide Detector’s test button is pressed. 355555557 - SD or CO emergency restore When the Smoke Detector (SD) or Carbon Monoxide Detector (CO) emergency status is restored.
  • Page 34: Ctc-1052 Programming Command Table

    5.4. CTC-1052 Programming Command Table TERM DTMF DTMF DTMF CHARACTER COMMAND OPERATION DEFAULT NATO COMMANDS Telephone number 1 No number Telephone number 2 No number Telephone number 3 No number Telephone number 4 No number Telephone number & GPRS/IP for alarm report...
  • Page 35 DTMF DTMF TERMI- DTMF CHARACTER COMMAND OPERATION DEFAULT NATOR COMMANDS Mobility time Mobility time 00= Disable, 01 ~ 36= 1 ~ 36 Hours disable Follow-On Choice, 0 = Wait command, Two-way voice 1 = Listen, 2 = Two way voice communication communication Follow-On mode &...
  • Page 36: Ctc-1052 Sms Remote Programming Command Table

    5.5. CTC-1052 SMS Remote Programming Command Table If the SMS Keyword is set as PROG, and Access Code is set as 1111 (factory default). CORRESPON- DING DTMF ITEM COMMAND EXAMPLE & USAGE DEFAULT CHARACTER COMMANDS PROG 1111 KEYWD:IPOG Keyword KEYWD...
  • Page 37 CORRESPON- DING DTMF ITEM COMMAND EXAMPLE & USAGE DEFAULT CHARACTER COMMANDS Reporting PROG 1111 FMATG:0 method for To set the reporting methods for all 4 Telephone numbers all 4 FMATG 0=Contact ID, 1=Scancom, 2=Tunstall, 3=Speech, Contact ID Telephone 4=SMS CID numbers Reporting PROG 1111 FMAT1:0...
  • Page 38 CORRESPON- DING DTMF ITEM COMMAND EXAMPLE & USAGE DEFAULT CHARACTER COMMANDS PROG 1111 FOLTI:02 Follow-on & 05 = To set the duration for follow-on & two-way voice two-way FOLTI communication period 5 minutes period 01-10=1-10 minutes PROG 1111 OFFST:1 To set the off-set time Off-set time OFFST 1=1 Hour, 2=2 Hours, 3=3 Hours...
  • Page 39 PROG 1111 APNSR:INTERNET Access APNSR To set/change the Access Point Name (APN server, 31 No APN Point Name digits) PROG 1111 GPUSE:123 No user User name GPUSE To set/change the user name name Input 1 to 15 alphanumeric characters PROG 1111 GPASS:65536 Password GPASS To set/change the password...
  • Page 40 This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.

Table of Contents