Advertisement

Quick Links

CTC-1052-QT-DT35A
User Manual
Sep 4, 2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CTC-1052-QT-DT35A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Climax CTC-1052-QT-DT35A

  • Page 1 CTC-1052-QT-DT35A User Manual Sep 4, 2020...
  • Page 2: Table Of Contents

    4.1. 2. Dial in Twice (Ring Count Disable) ......................5 4.2. Programming Your 1052-QT-DT35A __________________________________________6 4.3. SMS Remote Programming ________________________________________________17 4.3.1 CTC-1052-QT-DT35A SMS Remote Programming Command Table ............18 4.4 PC Programming Mode ____________________________________________________22 4.4.1 Function Tabs ..............................25 4.4.2 Profile ................................. 35 5.
  • Page 3 5.1.3. CTC-1052-QT-DT35A Low Battery ......................38 5.1.4. CTC-1052-QT-DT35A Battery Disconnection ..................38 5.1.5. Devices Low Battery ............................. 39 5.1.6. Automatic Check-in Report = Periodic Test Call ................... 39 5.1.7. Mobility Timer ..............................39 5.1.8. Country Code ..............................39 5.1.9. Temperature ..............................40 5.2.
  • Page 5: Application Overview

    REAR VIEW 3. RESET BUTTON — Press once in normal mode to reset mobility timer. (see command 44). — Before CTC-1052-QT-DT35A dials out for alarm reporting, press once to cancel the alarm reporting. 10. Power Button — During or at-the-end of conversation, press once to terminate two-way —...
  • Page 6: The Power Supply

    11. DC Jack 1.3. Insert SIM Card — DC switching power connection CTC-1052-QT-DT35A Panel features built-in Cellular network communication facility to report to the Monitoring Station. 12. Programming Telephone Jack — The programming cable (QT cable A) needs to be plugged into this jack ...
  • Page 7: Programming Cable And Local Firmware Update Cable

    (Wi-Fi) devices. 1.5. Programming cable and Local Firmware Update cable  CTC-1052-QT-DT35A has a QT cable A for PC programming and a QT cable B for Local firmware update (optional items, sold separately). To perform PC programming, the QT cable ...
  • Page 8: Learn-In The Devices

    There are three methods to learn in devices: CTC-1052-QT-DT35A. When pressed, the command learning, local learning, and using CTC-1052-QT-DT35A will emit one beep Device ID. The system can learn a total of 20 sound initially, and then emit a double beep sensors.
  • Page 9: Remove The Devices

    Please refer to 4.4 PC Programming Mode By using Command 41, you can set the number 4.4.1.5 Device for detailed instructions. of rings for CTC-1052-QT-DT35A to answer (00- Rings is set as factory default). Step 1. Dial CTC-1052-QT-DT35A and wait for 3.2.
  • Page 10: Programming Your 1052-Qt-Dt35A

    Function # DTMF Step 5. Enter (#) to terminate the Command Selection Operation. Step 6. CTC-1052-QT-DT35A will emit a short beep, indicating successful programming. 1. CC = 2-digit DTMF Command The maximum interval between key strokes is 2 2. # = Termination of the DTMF Command minutes.
  • Page 11 QT-DT35A will auto-answer the call without successful. checking access code or any button press. If you hear CTC-1052-QT-DT35A emit one  beep instead, that means the programming CTC-1052-QT-DT35A will match the of the 1 telephone number has failed.
  • Page 12 The latest Command (05-06) setting(s) & 4 Tel. #s (14) will overwrite any previously enter Tel & 5 GPRS. #s (15) setting(s).  When CTC-1052-QT-DT35A reports, Tel & 6 GPRS. #s (16) GPRS has the highest priority. & 3 Tel. #s (23) Command 10-14 &...
  • Page 13 Tel. Command 31 Numbers respectively. Ringer Enable for Incoming Calls Available Options:  CTC-1052-QT-DT35A can be programmed  to emit a ring tone as an audio alert, or Function Method silent for incoming calls. Selection Function Selection Result...
  • Page 14 Command 35 Command 38 Silent Mode Follow-On & Call-Back Function CTC-1052-QT-DT35A can be selected to  operate in Silent Mode. This will mute all normal operation warning beeps, guard Function Selection Result time tone and key tone.
  • Page 15 Factory Default is (00) Rings.  When the correct Access Code is received, <NOTE> CTC-1052-QT-DT35A will then open a Full-  Duplex Communication to allow the Call When (00), it means CTC-1052-QT- Recipient to speak to CTC-1052-QT-DT35A DT35A cannot auto-answer the call by directly.
  • Page 16 Monitoring Center. telephone numbers assigned to SMS reporting method in Command 20-24.  When CTC-1052-QT-DT35A is in idle mode, press and hold the Learn Button for 15 seconds, until you hear a long beep. Release the button and the Command 44 Mobility timer will be suspended.
  • Page 17 Monitoring Center. once, and then send report according to the setting of Command 43 - Test call.  When the supervisory timer expires and no supervision signal is received from WTR , Function CTC-1052-QT-DT35A will send Result Selection Supervisory Failure report.
  • Page 18 To minimize the Alarm Reporting threshold. impact of echo, if you raise speaker volume, please sure lower  When CO2 concentration value reaches or microphone sensitivity, and vice versa. exceeds the Alarm Reporting threshold, CTC-1052-QT-DT35A will report Alarm to CMS.
  • Page 19  This function will be disabled if alarm Time Delay time for fall sensor. activation is made from a Silent  CTC-1052-QT-DT35A can be programmed Device (learnt using Command #93). to delay alarm reporting triggered by a fall  Factory default is (0), OFF.
  • Page 20 Device Button!” message will pop up. emit a long beep and automatically returns to Programming mode. Step 2: Press the learn button on the device Step 3: CTC-1052-QT-DT35A will emit 2 within 20 seconds. beeps to indicate that Silent Pendant...
  • Page 21: Sms Remote Programming

    <NOTE> return to Programming mode.  Prior to procced, please be reminded to Step 3: CTC-1052-QT-DT35A will emit 2 change the language setting of your mobile beeps to indicate the device is phone to English. learnt-in successfully.
  • Page 22: Ctc-1052-Qt-Dt35A Sms Remote Programming Command Table

    4.3.1 CTC-1052-QT-DT35A SMS Remote Programming Command Table  If the SMS Keyword is set as PROG, and Access Code is set as 8744 (factory default). CORRESPON- DING DTMF COMMAND EXAMPLE & USAGE ITEM DEFAULT CHARACTER COMMANDS PROG 8744 KEYWD:IPOG Keyword...
  • Page 23 CORRESPON- DING DTMF COMMAND EXAMPLE & USAGE ITEM DEFAULT CHARACTER COMMANDS Reporting PROG 8744 FMAT2:0 method for FMAT2 To set the reporting method for Telephone number 2 3=Speech Telephone 3=Speech, 4=SMS CID number 2 Reporting PROG 8744 FMAT3:0 method for FMAT3 To set the reporting method for Telephone number 3 3=Speech...
  • Page 24 CORRESPON- DING DTMF COMMAND EXAMPLE & USAGE ITEM DEFAULT CHARACTER COMMANDS PROG 8744 SUPPR:0 To set the supervision timer Supervision SUPPR 0=Disable, 1=4 Days, 2=5 Days, 3=6 Days 0 = Disable 4=7 Days, 5=8 Days, 6=9 Days, 7=10 Days PROG 8744 LANGU:0 To set voice prompt language.
  • Page 25 CORRESPON- DING DTMF COMMAND EXAMPLE & USAGE ITEM DEFAULT CHARACTER COMMANDS PROG 8744 GPASS:65536 Password GPASS To set/change the password password Input 1 to 5 digits Reset to factory FTSET PROG 8744 FTSET:YyS default PROG 8744 DEVDL:SCMD Delete To delete devices learnt into the panel. DEVDL Device SCMD:...
  • Page 26: Pc Programming Mode

    Step 3. Connect the PC Programming cable to the USB Extension Cable. Step 4. Connect the USB Extension Cable to the USB port on your computer. See Figure 1 for connection diagram between medical panel and computer. See Figure 2 for CTC-1052-QT-DT35A connection jack locations. Figure 1 Figure 2 Installing The USB Driver Step 5.
  • Page 27 USB port. To download 1052-QT-DT35a-Tool programming software, open your browser and type below URL in the address bar: https://www.climax.com.tw/climax-download-1052qt- dt35a.html. Step 7. 1052-QT-DT35a-Tool is a portable application and requires no installation. Simply unzip the file to a desired folder and double-click “1052-QT-DT35a-Tool” to execute the programming tool.
  • Page 28 Step 8. Select the COM port generated for CTC-1052-QT-DT35A after installing the USB Driver (the USB port connected to CTC-1052-QT-DT35A), enter the password (default 8744), and then click “Open”. A “Read All command success!” message will pop up. Click “OK”, and the current 1052- Step 9.
  • Page 29: Function Tabs

    4.4.1 Function Tabs To program the CTC-1052-QT-DT35A Control Panel, click on different function tabs to see and edit CTC-1052-QT-DT35A functions. 4.4.1.1 Report The “Report” tab allows the user to configure report settings. 21# - 24# Reporting Method [Tel. Number 1-4]: - You can program the Alarm reporting method for each Tel.
  • Page 30 - In each field, key in an Account Number of 4 or 6 or 8 digits. After editing and updating, click write to apply new settings. 4.4.1.4 Settings The “Settings” tab allows you to program general configuration for CTC-1052-QT-DT35A. Click “Write” when you have completed all settings to confirm.
  • Page 31 37# AC Fault Report: - When set to ON, CTC-1052-QT-DT35A will send a Fault Report after a continuous one hour of AC Fault condition is detected. - When set to OFF, CTC-1052-QT-DT35A will not send an AC fault report.
  • Page 32 Delay Time for Fall Sensor, instead of Command #42 Guard Time Delay. 43# Periodic Test Call: - CTC-1052-QT-DT35A can be programmed to make test calls periodically (every 0 – 7 days, 0- 23 hours, and 0-59 mins). Whenever programming mode is accessed, CTC-1052-QT-DT35A will reset the Periodic Test Call timer.
  • Page 33 - When the supervisory timer expires and no supervision signal is received from WTR, CTC- 1052-QT-DT35A will send a Supervisory Failure report. 53# Voice Prompt Language: - Select the voice prompt language for CTC-1052-QT-DT35A. Available options include English, Arabic, Spanish, Russian, and beep only. 54# Fall Sensor Sensitivity - Select the Fall Sensor 3 Sensitivity.
  • Page 34 20 sensors. All learnt-in devices will be assigned to zone 1-20 sequentially. 93# Learn-In Silent Device: - This is used for learning in silent devices. When CTC-1052-QT-DT35A receives the alarm signal from a Silent Device, it will not sound any warning beeps during Reporting and Guard time period.
  • Page 35 <NOTE>  Learning can only be completed within the signal reception range of CTC-1052-QT-DT35A. If no signal is received within 20 sec, a “Learning Fail” message will pop up, and CTC-1052- QT-DT35A will automatically return to Programming mode.
  • Page 36 81# Remove Zone 1 Device Click “Remove” to remove zone 1 device from CTC-1052-QT-DT35A. A message “Remove Zone 1 Device command success!” will pop up. 82# Remove Zone 2 Device Click “Remove” to remove zone 2 device from CTC-1052-QT-DT35A. A message “Remove Zone 2 Device command success!”...
  • Page 37 - When an incoming call matches with any of the programmed Caller ID(s), CTC-1052-QT- DT35A will auto-answer the call without checking access code or any button press. - CTC-1052-QT-DT35A will match the numbers starting from the last digit, and verify 10 digits at the most.
  • Page 38 55# High Temperature Reporting: - Set the High Temperature Reporting threshold in degrees Fahrenheit. (32°F ~ 212 °F) - Factory Default is 95°F. 56# Low Temperature Reporting: - Set the Low Temperature Reporting threshold in degrees Fahrenheit. (32°F ~ 212 °F) - Factory Default is 47°F.
  • Page 39: Profile

    Adjust Brightness Color: - Input the brightness color level (1, 2, 3). - 1: low, 2: normal, 3: high 4.4.2 Profile The Profile function allows you to create and edit different setting profiles which can be easily accessed in the future for quick programming. Current Setting After reading the configuration of CTC-1052-QT, the Profile scroll down bar will now display “Current Setting”...
  • Page 40 After editing the settings, click “Save Profile” to save the profile settings. A pop-up window will indicate the profile has saved. You can use this profile in the future to apply the same setting to other CTC-1052-QT. Save Profile As After editing the settings of a profile, you can make a copy of the current profile with a different name by clicking “Save Profile As”.
  • Page 41 Select a profile and click on “Delete Profile”. A pop-up window will ask you to confirm the selection: Select “Yes” to delete the profile, or “No” to return to the previous page. Profile Backup & Transfer The profiles that you created and saved are stored as text files in the “Profile” folder under the directory where the 1052-QT-Tool files are extracted in your local computer.
  • Page 42: Operation

    When the low battery condition lasts for 4 -   If the speaker volume and microphone 6 mins, CTC-1052-QT-DT35A will report to sensitivity was adjusted, the adjusted the Monitoring Center and the GREEN LED value will be kept for the next will flash slowly.
  • Page 43: Devices Low Battery

    When the battery disconnection lasts for  When the Mobility timer is not reset after 30 10-15 minutes, CTC-1052-QT-DT35A will minutes, CTC-1052-QT-DT35A will send a report to the Monitoring Center and the Mobility Timer Expired report to the GREEN LED will flash slowly.
  • Page 44: Temperature

    After High Temperature report, Time Delay will reported temperature drops under 95°F/35°C, the immediately. CTC-1052-QT-DT35A will play panel will send High Temperature Restore voice prompt “Fire Alarm,” “Carbon report to CMS. Monoxide Alarm,” “Water Leak Alarm” to inform the user of the alarm at hand.
  • Page 45: Confirmation Voice Prompt

     this step. The Guard Time Delay triggered from a fall detection (of a Fall Sensor) has its  IP Address: Central Monitoring Station timer (programmed using server IP. Please refer to 4.3.1 1052-QT- Command 66). The CTC-1052-QT- DT35A SMS Remote Programming Table DT35A will play voice prompt “A fall has on how to set CMS IP Address(es) (SMS been detected,”...
  • Page 46: Speech Reporting Method

     If Speech Reporting Method is selected, Upon receiving the correct Access Code after dialing, CTC-1052-QT-DT35A will and the (#) key, CTC-1052-QT-DT35A will open a two-way voice communication then open a Full-Duplex Communication to between the Call Recipient and CTC-1052- allow the caller to communicate directly.
  • Page 47: Report Sequence

    Way” communication mode. Control Panel will try all report destinations for up to 15 times in total. <NOTE> If more than 1 report destinations are set to  Speech Reporting made under Silent a report method (e.g. GPRS), the panel will Mode or using a Silent Device will consider report...
  • Page 48: Walk Test (Range Test)

    Ready to learn sensor.” Release the observe the range for its operation. Learn Button right after the double beep and the voice prompt. Step 3. If CTC-1052-QT-DT35A responds with one long beep, then the particular Step 2. CTC-1052-QT-DT35A device is within the operation range.
  • Page 49: Factory Reset

    The message composition for CID Event code is 5.6 Factory Reset in the form: ACCT MT QXYZ GG C CTC-1052-QT-DT35A will clear all programmed parameters by the following sequence: Step 1. Press the Power Button to power off And is explained in the following table: the panel.
  • Page 50 “Time for Medicine” alarm 147 - Sensor Supervisory Failure  expires (default: 30 minutes).  When CTC-1052-QT-DT35A is unable 341 - Medication Dispenser Mechanism  to receive the signal transmitted from the Wrist Transmitter for a pre-set ...
  • Page 51 Mobility Timer Expired reporting. <NOTE>  This event code will be sent with a fixed zone number of 071...
  • Page 52: Ctc-1052-Qt-Dt35A Programming Command Table

    6.2. CTC-1052-QT-DT35A Programming Command Table TERM DTMF DTMF DTMF COMMAND OPERATION CHARACTER DEFAULT NATO COMMANDS To Set Caller ID (201-220) Enter: Caller ID Sequence + * + Caller ID Caller ID: Note: Caller ID Sequence: 201-220 8008604230 Symbol: * Caller CID:...
  • Page 53 DTMF DTMF TERMI- DTMF COMMAND OPERATION DEFAULT CHARACTER NATOR COMMANDS Test Call: DDHHMM DD:00-07=0-7 Day(s) HH= 00-23=0-23 Hour(s) 7 Days MM=00-59=0-59 Min(s) 000000= Disable Mobility time Mobility time 00= Disable, 01 - 36= 1 - 36 Hours disable Two-Way Period, 01=1 min, 02=2mins, 03=3mins, 04=4mins, 10 minutes 05=5mins, 06=6mins, 07=7mins, 08=8mins,...
  • Page 54: Ctc-1052-Qt-Dt35A Voice Prompts

    6.3. CTC-1052-QT-DT35A Voice Prompts The Control Panel plays voice prompts on important occasions to report its condition or remind you to take a specific action. Information on voice prompts is provided in the chart below. Voice Prompt Condition Played once after long pressing (6 seconds) the Learn Button on the Release the Button Control Panel to enter learning mode.
  • Page 55 FCC Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation.

Table of Contents