(09) 24-hour Fire
This sensor type is continuously armed 24-hours a day. A sensor configured to this type
will trigger the local alarm fire sounder and the external siren regardless of the mode the
system is in. Typical use would be for wireless smoke detectors. This sensor type is always
active and cannot be bypassed.
(16) 24-hour Fire with V erification
This sensor type is continuously armed 24-hours a day. A sensor configured to this type
can trigger the local alarm fire sounder and an external siren (optional equipment)
regardless of the mode the system is in. This sensor type is always active and cannot be
bypassed.
For verification, this sensor type must report twice in two minutes, or remain violated for
30 seconds. A fire alarm will be transmitted immediately from the control panel IF any
other monitored fire sensor activates within a two-minute period.
Emergency
DEFAULT: Enabled
The hub's emergency button can be enabled or disabled. The panel's emergency button
is displayed by pressing the Emergency button.
The default setting allows the emergency button to be displayed when pressing
l
the Emergency button, and enables the customer to manually trigger an
emergency and sound an audible alarm.
To disable and not display emergency button, select disabled.
l
Quick Arming
Quick Arming allows you to arm your system without having to enter a User Code.
When you press the Stay or Away button, the system will start to arm without requesting
a User Code. The default setting is On.
Off
On
Quick Bypass
Normally sensors that are open at the time the system is armed will require force
bypassing by entering your User Code. The system can be set so a User Code is not
40