Download Print this page
Iso-Tech ICM A9 Instruction Manual

Iso-Tech ICM A9 Instruction Manual

Electrical clamp-multimeter

Advertisement

Quick Links

Instruction Manual
ICM A9
Electrical Clamp-Multimeter
EN
ICMA9
Warning
Safety
. . . . . . . . . .
. . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . . .
Read First
Safety Information
To ensure safe operation and service of
this Clamp-multimeter, read these
instructions completely before use and
comply with them fully when using it.
Failure to observe these warnings can
result in severe injury or death.
- Avoid working alone so assistance can
be rendered.
- Do not use test leads or the Tester if
they look damaged.
- Do not use the Tester if the Tester is
not operating properly or if it is wet.
- Use the Tester only as specified in the
Instruction card or the protection by
the Tester might be impaired.
- Use extreme caution when working
around bare conductors or bus bar.
Contact with the conductor could
result in electric shock.
- Do not use the Tester to measure volt-
ages in circuits that could be damaged
by the Tester's low input impedance
(approximate 4KΩ)
- Use caution with voltages above 30 V
ac rms, or 60 V dc. These voltages
pose a shock hazard.
Symbols as marked on the Tester
and Instruction card
Risk of electric shock
See instruction card
DC measurement
Equipment protected by double or
reinforced insulation
< Battery
Earth
AC measurement
Conforms to EU directives
Application around and removal
E
from hazardous live conductors is
permitted
Do not discard this product or
throw away
Power On / Off
The Meter displays Battery Capacity
when powering up. Please replace the
battery when 0% is shown.
Caution
The Tester powers up in Ω / continuity
mode.
Auto Power Off
Auto Power Off Enable /
Disable
Auto Hold Enable / Disable
Self-Testing Aid
Fail of usage
Ready to use
Do not measure while powering up, it
will cause Self-Testing failure.
Caution
Do not use the Meter when "FAIL" is
shown. Undiscovered failure could exist
even "FAIL" is not shown.
Continuity

Advertisement

loading

Summary of Contents for Iso-Tech ICM A9

  • Page 1 To ensure safe operation and service of this Clamp-multimeter, read these Instruction Manual instructions completely before use and ICM A9 comply with them fully when using it. Failure to observe these warnings can Electrical Clamp-Multimeter result in severe injury or death.
  • Page 2 • AC V / DC V Input Impedance AC A Data Hold Beep Guard ≧ 4K for input voltage up to 30V. Caution The internal sounder will beep continu- CAT.Ⅲ.600V Impedance increases with input voltage ously with LCD display flashing in two When connecting the test leads to the with respect to to approximate 375KΩ...
  • Page 3 Priority of function 1-2 Environmental Conditions 1-3 Electrical Specifications Maintenance Do not attempt to repair this Tester. Accuracy is ±(% reading + number Indoor Use. The LCD display shows It contains no user-serviceable parts. Calibration : voltage mode when the of digits) at 23°C ±...
  • Page 4 Asia contamination or abnormal conditions of operation or handling. Iso-Tech Any implied warranties arising from the 460 Alexandra Road, #15-01A sale of this product, including but not lim- PSA Building...