Iso-Tech ICM A7-4 Instruction Manual

Electrical clamp-multimeter

Advertisement

Quick Links

Instruction Manual
ICM A7-4
Electrical Clamp-Multimeter
To ensure safe operation and service of
this Clamp-multimeter, read these
instructions completely before use and
EN
comply with them fully when using it.
Failure to observe these warnings can
result in severe injury or death.
- Avoid working alone, so assistance can
- Do not use test leads or the instrument
- Do not use the instrument if it is not
- Use the instrument only as specified in
ICM
A7-4
- Use extreme caution when working
- Wear appropriate Personal Protective
- Do not hold the instrument beyond the
- Use caution with voltages above 30 V
Symbols as marked on the
instrument and instructions.
Warning
Safety sheet
. . . . . . . . . .
. . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . . .
Read First
Safety Information
<
be rendered if required.
if they look damaged.
E
operating properly or if it is wet.
these Operating Instructions, or the
TEST EQUIPMENT RISK ASSESSMENT
protection provided by the instrument
Users of this equipment and or their
may be impaired.
employers are reminded that Health and
Safety Legislation require them to carry
out valid risk assessments of all electri-
around bare conductors or bus bar.
cal work so as to identify potential
Contact with a hazardous live conduc-
sources of electrical danger and risk of
tor could result in electric shock.
electrical injury such as from inadvertent
short circuits. Where the assessments
Equipment if working where hazardous
show that the risk is significant then the
live parts are accessible.
use of fused test leads constructed in
accordance with HSE guidance note
Tactile Barrier, or allow fingers to pro-
GS38 " Electrical Test Equipment for
trude past it.
use by Electricians" should be used.
The purpose of the barrier is to provide
adequate clearance between the op-
erator and a hazardous live conductor.
ac rms, or 60 V dc. These voltages
pose a shock hazard.
Off / On
Risk of electric shock
Refer to operating instructions.
DC measurement
Equipment protected by double or
reinforced insulation
Battery
Earth
Auto Power Off
AC measurement
Conforms to EU directives
May be used on uninsulated
Conductors.
Volts AC
Warning
Do not apply more than 600V rms
ac between the instrument terminals
and earth ground .
Volts DC
30min
Warning
Do not apply more than 600V rms
dc between the instrument terminals
and earth ground .

Advertisement

loading

Summary of Contents for Iso-Tech ICM A7-4

  • Page 1 ..Refer to operating instructions. Read First Instruction Manual Volts DC DC measurement ICM A7-4 Safety Information Equipment protected by double or Electrical Clamp-Multimeter To ensure safe operation and service of reinforced insulation...
  • Page 2 Resistance Amps AC Display Hold Shock vibration : SPECIFICATIONS Sinusoidal vibration per MIL-T- 1-1 General Specifications 28800E (5 ~ 55 Hz, 3g maximum). CAT.Ⅲ.600V LCD display digits : 3 1/2 digit large scale LCD readout. with respect to Display count : 2000 counts. earth for the jaw.
  • Page 3 Asia operation or handling. Iso-Tech Any implied warranties arising from the 460 Alexandra Road, #15-01A sale of this product, including but not lim- PSA Building...