Advertisement

Quick Links

Operating instructions
(Translation of the original operating instructions)
VIROLINE SMART
TEKA Absaug- und Entsorgungstechnologie GmbH, Millenkamp 9, D-48653 Coesfeld,
Tel.: +49 2541-84841-0, E-Mail: info@teka.eu, www.teka.eu
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VIROLINE SMART and is the answer not in the manual?

Questions and answers

Summary of Contents for Teka VIROLINE SMART

  • Page 1 Operating instructions (Translation of the original operating instructions) VIROLINE SMART TEKA Absaug- und Entsorgungstechnologie GmbH, Millenkamp 9, D-48653 Coesfeld, Tel.: +49 2541-84841-0, E-Mail: info@teka.eu, www.teka.eu...
  • Page 2: Table Of Contents

    Table of contents 1. General 2. Description of the system elements 2.1. Illustration of the system elements 2.2. Functionality of the system 2.3. Intended use 3. Safety instructions 3.1. Definition of the hazard symbols 3.2. General safety instructions 4. Storage, transport and installation of the device 5.
  • Page 3: General

    14.2.3. Electrical test of the electrical lines and earthing connections 1. General Congratulations on purchasing the product from TEKA. Our engineers ensure that our devices reflect the state of the art through continuous development. Nevertheless, misuse or misconduct can endanger your safety. Please observe the following for a...
  • Page 4: Description Of The System Elements

    2. Description of the system elements 2.1. Illustration of the system elements Installation example: Z.Nr. 20393701 Pos.1 Pos.5 Suction grille Pos.2 Microfilter mats (2 pieces) Pos.6 Exhaust grille Pos.3 UV-C lamp Pos.7 Mains cable with plug Pos.4 Fastening eyelet BA_VIROLINE-SMART_200921_EN 12.01.2022...
  • Page 5: Functionality Of The System

    2.2. Functionality of the system A fan admits the air. The contaminated air is guided through a microfilter into the stable housing. In the housing, the germs are efficiently eliminated by means of a high-performance UV-C lamp. In this way, the device progressively cleans all the air in the room.
  • Page 6: General Safety Instructions

    3.2. General safety instructions WARNING Dangers arising from improper use / unauthorised operations. The operator must ensure that their authorised personnel are familiar with all the safety indications in this manual in advance. The operator is responsible for ensuring that all work is carried out by authorised and qualified personnel.
  • Page 7: Commissioning

    5. Commissioning WARNING Dangers arising from a defective condition of the unit. There is also a risk to the eyes if there is a direct view of the UV-C lamp. Make sure that the measures described in this chapter are completed before the commissioning of the unit.
  • Page 8 Procecure: ● To control the “VIROLINE SMART WiFi”, choose a terminal device that is already integrated in the existing WLAN. Alternatively, add the required terminal device to the WLAN. ● Download the required app “Smart Life - Smart Living”onto your terminal device: Android: https://play.google.com/store/apps/details?id=com.tuya.smartlife&hl=de...
  • Page 9 ● Select your WLAN. You now see a prompt telling you to reset the device. To do this, press the button (C) on the inside built receiver. Actuate this using the wooden stick supplied through the opening "A", so that the control lamp of the inside built receiver starts to flash quickly. As soon as the lamp starts to glow permanently, you must tick “Next Step”...
  • Page 10: Attach The Plug

    5.3. Attach the plug The supplied plug Ø6 mm must be attached to the opening “A” if not already done. BA_VIROLINE-SMART_200921_EN 12.01.2022...
  • Page 11: Operating The System

    6. Operating the system 6.1. Explanation of the operating elements Operating elements for the device control Representa Designation Description / function tion Version “Basic”: By means of this switch, the device is switched on and off. ON-OFF-switch When the device is switched off, it is not disconnected from the power supply.
  • Page 12: Maintenance

    7. Maintenance In accordance with national regulations, the operator is obliged to carry out repeat and functional tests. Unless otherwise specified by national regulations, we recommend regular visual inspections and functional tests of the device as described in the chapter “Maintenance intervals”. You find the chapter “Maintenance intervals”...
  • Page 13: Reset To Maintenance State

    To do this, release the 4 screw connections of both grilles. ● Replace the microfilter mats with new ones. Only use TEKA spare filters. Otherwise the proper functioning of the unit is not guaranteed. ● Screw on the protective grilles again.
  • Page 14: Recplacing The Uv-C Lamp

    Now carefully pull the UV-C lamp out from its holder. ● Insert the new UV-C lamp. Only use TEKA spare parts. Otherwise the proper functioning of the unit is not guaranteed. ● Mount the inner protective grille, the microfilter mat and the exhaust grille again.
  • Page 15: Dismantling / Disposal

    A recommissioning of the device must only occur if it is ensured that the system is functionally equivalent to the original state. Repairs may only be carried out by TEKA personnel or, after consultation with TEKA GmbH, by the personnel authorised by the operator.
  • Page 16: List Of Spare Parts

    “SMART Basic” 100311 for version “SMART WiFi” 100312 Other parts Article no. UV-C lamp 100310 11. Technical data Version VIROLINE SMART Basic VIROLINE SMART WiFi Supply voltage Frequency Type of current Engine power 0,027 0,038 Air flow volume max. m³/h...
  • Page 17: Ec Declaration Of Conformity

    This declaration will become void if the device is exposed to modifications that are not approved by the manufacturer in written form. Authorized representative for the technical documentation: TEKA Absaug- und Entsorgungstechnologie GmbH, Millenkamp 9, D-48653 Coesfeld (Jürgen Kemper, managing director) Coesfeld, 3rd july 2020 BA_VIROLINE-SMART_200921_EN 12.01.2022...
  • Page 18: Training Protocol

    13. Training protocol Designation of the device: VIROLINE SMART (This form can be used by the operator to document the training of the employees. Training should be performed by authorized personnel only. Refer to the instructions in Chapter "Safety Instructions")
  • Page 19: Maintenance Intervals

    Maintenance work must always be documented by means of a protocol. The approach of the maintenance measures is described in chapter "Maintenance". Maintenance interval Maintenance work Chapter recommended by TEKA determined by the operator Replacing the microfilter mats semi-annually (or check the degree of pollution)
  • Page 20 14.2.1. Visual inspection of the device Visual inspection: Observation that there are no visible safety-related defects. WARNING Danger arising from the ready to operate condition of the device. Follow the procedure as described in the chapter “Set to maintenance state”. The following steps must be carried out in the course of the visual inspection: ●...

This manual is also suitable for:

Viroline smart - basicViroline smart - wifi2111040021110700

Table of Contents