8. Dismantling / Disposal

Only authorised personnel may disassemble the machine.
WARNING
Dangers arising from electricity.
Before the dismantling of the machine it has to be disconnected from the power supply and
all supply lines.
CAUTION
Whirling up dust is possible due to the deposited dust.
During all work a suitable respiratory protection and protective clothing have to
be worn.
The operator is obliged to store and dispose of the collected dust in accordance with national or
regional regulations.

9. Diagnostics and troubleshooting

A list of possible system errors is provided in the table.
A recommissioning of the device must only occur if it is ensured that the system is functionally
equivalent to the original state. Repairs may only be carried out by TEKA personnel or, after
consultation with TEKA GmbH, by the personnel authorised by the operator.
Adhere to the instructions in the chapter "Safety instructions" and " Maintenance" when carrying out any
repairs. If in doubt, contact our TEKA service department:
Tel:
+49 2541-84841-0
E-mail: info@teka.eu
Fault
System does not start.
Suction power too low
BA_VIROLINE-SMART_200921_EN
Cause
Plug power supply is missing or
incorrectly inserted.
No power at outlet.
Filter element is saturated.
Suction line contracted.
Exhaust line contracted.
Removal
Plug connector check power
supply / plug in correctly.
Further informations see chapter
"Operating the system".
Check the mains, remove error if
possible.
Replace the filter package,
dispose of old filter properly!
Check and fix.
Check and fix.