• The vacuum pressure switch has not been blocked by poor combustion or an obstruc-
tion in the exhaust pipe (re-activate it by blowing and sucking until you hear the switch
come into operation).
• The flue gas outlet pipe is inserted properly into the exhaust outlet.
• If the problem persists, consult your retailer.
2. If the stove goes out during operation:
• Check all the possibilities in previous section.
• Make sure that the thermal safety switch (re-settable
manually), on the inside back right of the stove, has been
reset.
• Before resetting the switch find the reason for its trig-
gering. Note that the thermal switch can only be reset
with electrical supply off and when the stove tempera-
ture has fallen below 93°C.

POWER FAILURE

Brief power failure: if there is a brief power failure (60 seconds), when the stove is at the
ignition stage or is operating normally, the stove is programmed to re-ignite itself. If the
power failure lasts for a longer, indefinite period, when the power returns the stove will go
into an extinguishing cycle, setting up for the next (manual or programmed) ignition. In this
case the display will indicate the failure by three yellow LED's lighting up alternately.
To reset the stove functions, switch it ON-OFF.
Temporary power failure: If there is a power failure lasting 3 / 5 minutes, with direct
flue gas exhaust pipes the stove may emit some smoke into the room, produced by the un-
burnt pellets present in the grate.
This does not constitute a safety risk.The problem can be avoided by installing the exhaust
pipe as shown on this handbook.
Electrical safety: the stove is protected against power surges by two fuses on the elec-
tronics board.
42

TECHNICAL SPECIFICATIONS

Fuel:
Minimum pellet consumption
Maximum pellet consumption
Pellet tank capacity
Exhsaust gas temperature
Maximum efficiency
Minimum efficiency
Rated efficiency
Minimum heat rating
Maximum heat rating
Nominal heat rating
CO emission produced during combustion:
at the minimum heat rating
at the nominal heat rating
Maximum absorbed power
Working power (P1):
Working power (P5):
Rated voltage
Rated frequency
Weight
Data obtained in the laboratory using pellets with thermal value 5300 Kcal/h, certified by SINAL..
The stove has been built in compliance with the following standards:
CE (European Directives)
RoHS (electronics board and components)
EN 60335-1 / EN 50165 / EN 50366 (electrical system and magnetic fields)
EN 14785 (pellet stove)
Tests and certification carried out at IMQ Primacontrol laboratories.

STANDARD EQUIPMENT:

• User's and installation handbook
• Diaphragm valve
• Four-channel remote control device.
(on/off, increase and decrease power, Man./Aut. selection)

OPTIONAL EQUIPMENT:

• External digital thermostat for the room
• GSM telephone modem (to allow control of the stove from a remote location)
FI 3
FI 4
DUAL -
FI 3 DUAL
FI 4
Natural wood pellets
0,55 kg/h
2,5 kg/h
2,2 kg/h
20 kg
256°C
87 %
78,88 %
79,35 %
2,3 kW
13,5 kW
11,5 kW
10 kW
0,040 %
0,020 %
340 W (during inition)
90 W
130 W
230 V
50 Hz
135 Kg