Pretty - Nice - LADy prEttY Pretty cer nicE Nice cer LadY Lady K iNstALLAtioN, user's AND mAiNteNANce hANDbook Presentation imPortANt iNFormAtioN reGArDiNG sAFety Preparations for installation inportant information for the user Fuel used important instructions before ingnition recommendations for using the stove correctly...
Pretty - Nice - LADy prEsEntation dear customer, We would first of all like to thank you for choosing an EcoWood product. our ecoWooD stoves and inserts are the result of experience and technical in- novation acquired after years of work in the energy sector.
Page 3
Pretty - Nice - LADy this stove operates only and exclusively with pellets (pressed wood sawdust). top quality pel- lets without impurities should be used. in order to obtain a constant flame with a pleas- ing appearance it is important to use 6 mm di- ameter pellets that are about 20 mm long, and as regular as possible.
DIN 51731 and ONORM-M 7135 (thermal value, residual humidity, diameter, quality of wood used...). ecowood cannot assume liability for poor operation of the stove if poor quality pellets are used. • use only pellets and never put other inflammable or combustible material in the stove.
Pretty - Nice - LADy • the gas output system works by negative pressure in the combustion chamber, there- fore slight positive pressure is formed in the flue gas exhaust pipe; for this reason it is very important to ensure that the exhaust pipe is free of blockages and fully sealed until it is outside the building.
Pretty - Nice - LADy instaLLation the stove must be installed by qualified personnel, who must diligently follow all the rules for correct installation, respecting all the relevant technical, legal and safety standards in force at the time. When positioning the stove respect the distances shown in the drawing on the right.
Pretty - Nice - LADy if the gas exhaust pipe is installed as in the draw- rain protection ing on the right, a rain protection cover will be cover needed in addition to the requirements listed insulating sleeve above. insulating sleeve...
Pretty - Nice - LADy between the stove and the floor, if the latter could be inflammable, be sure to insert heat protection, ensuring it protrudes at the front and sides by at least 20 cm. connect the power supply cable to a 230 volt mains outlet.
Page 9
Pretty - Nice - LADy • the hot air fan comes on automatically about 15 minutes after ignition, at the first speed, and levels itself at the selected power for the normal operating cycle, 25 minutes after ignition. • it is possible to adjust the hot air fan separately from fuel loading rate (only for the first two power levels);...
Pretty - Nice - LADy maintEnancE Warning! Before carrying any maintenance, disconnect the power supply and wait for the stove to cool down completely. ORDINARy MAINTENANCE: Weekly, by the user • When the stove is not ignited and cold, remove and vacuum clean the ashes from the recovery tray.
Pretty - Nice - LADy Warning installation and extraordinary maintenance must be done only by skilled, technical personnel. • important notE: if the stove is connected to the outside by a metal flue gas ex- haust pipe, two conditions could be deleterious to good combustion.
Pretty - Nice - LADy opErating proBLEms and soLutions Warning! Only skilled technical personnel are allowed to dismantle the stove and work on the internal components. Before carrying out any operation whatsoever, disconnect the power supply and wait until the stove has completely cooled down.
Page 13
Pretty - Nice - LADy 2. if the stove goes out during operation: • check all the possibilities in previous section. • check whether the stove is ready for programmed cleaning after 2500 hours have ex- pired. the display will show cleaning/maintenance message.
Page 14
Pretty - Nice - LADy annEx: aLarm and notiFication All alarm and notification messages appear on the display, possible causes and solutions. clock not programmed problem: the time and date has not been set. the timers cannot be used. solution: set the time and date and any timers in the respective menu.
• For the first two years cleaning is carried out by technical staff who have been authorised by ecoWooD. • the guarantee is not applicable for damage caused by: weather conditions, chemicals, electro-chemicals, fire, negli- gence or improper use, failure to observe the legislation in force, faults in the electrical system, lack of maintenance, tampering with the product, an inefficient chimney, the use of unsuitable fuel;...