Ecowood Pretty Installation, Users And Maintenance Handdook

Advertisement

Quick Links

Advertisement

Table of Contents
loading

Summary of Contents for Ecowood Pretty

  • Page 1: Table Of Contents

    Pretty - Nice - LADy prEttY Pretty cer nicE Nice cer LadY Lady K iNstALLAtioN, user's AND mAiNteNANce hANDbook Presentation imPortANt iNFormAtioN reGArDiNG sAFety Preparations for installation inportant information for the user Fuel used important instructions before ingnition recommendations for using the stove correctly...
  • Page 2: Presentation

    Pretty - Nice - LADy prEsEntation dear customer, We would first of all like to thank you for choosing an EcoWood product. our ecoWooD stoves and inserts are the result of experience and technical in- novation acquired after years of work in the energy sector.
  • Page 3 Pretty - Nice - LADy this stove operates only and exclusively with pellets (pressed wood sawdust). top quality pel- lets without impurities should be used. in order to obtain a constant flame with a pleas- ing appearance it is important to use 6 mm di- ameter pellets that are about 20 mm long, and as regular as possible.
  • Page 4: Important Information Regarding Safety

    DIN 51731 and ONORM-M 7135 (thermal value, residual humidity, diameter, quality of wood used...). ecowood cannot assume liability for poor operation of the stove if poor quality pellets are used. • use only pellets and never put other inflammable or combustible material in the stove.
  • Page 5: Recommendations For Using The Stove Correctly

    Pretty - Nice - LADy • the gas output system works by negative pressure in the combustion chamber, there- fore slight positive pressure is formed in the flue gas exhaust pipe; for this reason it is very important to ensure that the exhaust pipe is free of blockages and fully sealed until it is outside the building.
  • Page 6: Installation

    Pretty - Nice - LADy instaLLation the stove must be installed by qualified personnel, who must diligently follow all the rules for correct installation, respecting all the relevant technical, legal and safety standards in force at the time. When positioning the stove respect the distances shown in the drawing on the right.
  • Page 7: Combustion Air Inlet

    Pretty - Nice - LADy if the gas exhaust pipe is installed as in the draw- rain protection ing on the right, a rain protection cover will be cover needed in addition to the requirements listed insulating sleeve above. insulating sleeve...
  • Page 8: Operation

    Pretty - Nice - LADy between the stove and the floor, if the latter could be inflammable, be sure to insert heat protection, ensuring it protrudes at the front and sides by at least 20 cm. connect the power supply cable to a 230 volt mains outlet.
  • Page 9 Pretty - Nice - LADy • the hot air fan comes on automatically about 15 minutes after ignition, at the first speed, and levels itself at the selected power for the normal operating cycle, 25 minutes after ignition. • it is possible to adjust the hot air fan separately from fuel loading rate (only for the first two power levels);...
  • Page 10: Maintenance

    Pretty - Nice - LADy maintEnancE Warning! Before carrying any maintenance, disconnect the power supply and wait for the stove to cool down completely. ORDINARy MAINTENANCE: Weekly, by the user • When the stove is not ignited and cold, remove and vacuum clean the ashes from the recovery tray.
  • Page 11: Mainenance Of The Smoke Exhaust Duct

    Pretty - Nice - LADy Warning installation and extraordinary maintenance must be done only by skilled, technical personnel. • important notE: if the stove is connected to the outside by a metal flue gas ex- haust pipe, two conditions could be deleterious to good combustion.
  • Page 12: Operating Problems And Solutions

    Pretty - Nice - LADy opErating proBLEms and soLutions Warning! Only skilled technical personnel are allowed to dismantle the stove and work on the internal components. Before carrying out any operation whatsoever, disconnect the power supply and wait until the stove has completely cooled down.
  • Page 13 Pretty - Nice - LADy 2. if the stove goes out during operation: • check all the possibilities in previous section. • check whether the stove is ready for programmed cleaning after 2500 hours have ex- pired. the display will show cleaning/maintenance message.
  • Page 14 Pretty - Nice - LADy annEx: aLarm and notiFication All alarm and notification messages appear on the display, possible causes and solutions. clock not programmed problem: the time and date has not been set. the timers cannot be used. solution: set the time and date and any timers in the respective menu.
  • Page 15: Declaration Of Conformity

    Pretty - Pretty cer - Nice - Nice cer - LADy - LADy k use: Domestic heating manufacturer: ecoWooD address: Via borgo, 36 - 36034 malo (Vi) tel. / fax: 0445 580725 / 0445 602079 notified laboratory: imQ primacontrol s.r.L. - kiwa s.p.A.
  • Page 16: Guarantee

    • For the first two years cleaning is carried out by technical staff who have been authorised by ecoWooD. • the guarantee is not applicable for damage caused by: weather conditions, chemicals, electro-chemicals, fire, negli- gence or improper use, failure to observe the legislation in force, faults in the electrical system, lack of maintenance, tampering with the product, an inefficient chimney, the use of unsuitable fuel;...

This manual is also suitable for:

Pretty cerLadyNiceLady kNice cer

Table of Contents