Nortek C6B-T Installation Instructions Manual

Split system uncased indoor coils

Advertisement

Quick Links

Split System Uncased Indoor Coils
Installation Instructions
CAUTION:
Read the Installation Instructions
supplied with furnace/air handler
and observe all safety r e q u i r e m e n t s
o u t l i n e d i n instructions and/or
furnace/air h a n d l e r m a r k i n g s
b e f o r e proceeding with installation
of the coil.
These instructions are primarily
intended to assist qualified individuals
experienced in the proper installation
of this appliance. Some local and
national codes require licensed
installation/service personnel for
this type of equipment. Read all
instructions carefully before starting
the installation.

Advertisement

Table of Contents
loading

Summary of Contents for Nortek C6B-T

  • Page 1 Split System Uncased Indoor Coils Installation Instructions These instructions are primarily CAUTION: intended to assist qualified individuals experienced in the proper installation Read the Installation Instructions supplied with furnace/air handler of this appliance. Some local and and observe all safety r e q u i r e m e n t s national codes require licensed o u t l i n e d i n instructions and/or installation/service personnel for...
  • Page 3: Table Of Contents

    Table of Contents 1. General Information ......................... 4 2. Coil Installation ........................4 Upflow Furnace/Air Handler ..................4 Downflow/Horizontal ....................4 3. Pressure Verification ....................... 4 4. Refrigerant Line Connections ....................5 5. Completing the Installation..................... 5 Condensate Drain ......................5 Air Filters ........................
  • Page 4: General Information

    1. GENERAL INFORMATION 1. Disconnect all electrical power to the furnace. These C-series coils are designed for upflow 2. If needed, make a plate to adapt the coil and downflow applications. They are equipped to the furnace/air handler air discharge with brazing stub refrigerant connections for opening.
  • Page 5: Refrigerant Line Connections

    11. It is recommended to wrap a wet rag around 4. REFRIGERANT LINE the suction line between the sensing bulb CONNECTIONS and the lineset braze joint before applying any heat. WARNING: 12. Braze the individual connections with dry nitrogen flowing through the joint to eliminate internal oxidation and scaling.
  • Page 6: Refrigerant Charging

    To ensure optimum system performance and refrigerant lines and drain line where required. Reinstall all inner and outer panels of the furnace/ to minimize the possibility of equipment failure, air handler that were previously removed to the following periodic maintenance should be install the indoor coil.
  • Page 8 Figure 3. Condensation Deflector Positioning INSTALLER: PLEASE LEAVE THESE INSTALLATION INSTRUCTIONS WITH THE HOMEOWNER Specifications & illustrations subject to change without notice or incurring obligations (07/15). O’Fallon, MO, © Nortek Global HVAC LLC 2015. 708821D (Replaces 708821C) All Rights Reserved.

This manual is also suitable for:

C6ba-tC6bh-t

Table of Contents