Zero-voltage relay switching insert
■
If multiple circuit breakers supply dangerous voltages to the device or load,
couple the circuit breakers or label them with a warning, to ensure disconnec-
tion is guaranteed.
■
Connect the 2-wire extension (3), the 3-wire extension (4) and the push-button
with NO contact (5), optionally.
Lit push-buttons must have a separate N terminal.
■
Fit the switch insert in the appliance box, the connection terminals must be at
the bottom.
Do not attach or replace the cover under voltage, otherwise this might cause a
malfunction.
■
Attach the frame and the cover.
■
Switch on mains voltage.
The load can be switched by briefly pressing the TEST button (1).
Setting the time function
Press the TEST button (1) for longer than 4 seconds.
■
LED lights up in the colour of the set time, see table.
■
Release the TEST button (1) briefly and then press it repeatedly until the LED
lights up in the colour of the desired time.
The set time is automatically saved after 30 seconds or after pressing the
TEST button (1) for approx. 4 seconds. When the LED goes out, the saving
process was successful.
LED colour
green
white
blue
yellow
red
Connecting and mounting the device as a room temperature controller (see figure 3)
Recommended installation height: 1.50 m.
82406002
22.08.2022
Set time
Function off
1 minute
5 minutes
30 minutes
60 minutes
5 / 7