5.8

Load bar

Fig. 16
WARNING
Overload
Danger to life and limb due to an overload.
The maximum permissible safe working load is 270 kg for non-guided loads which are allowed to swing freely.
5.9

Connecting the electric equipment

Mains connection
First check to ensure that the voltage and frequency specified on the rating plate match your mains supply.
The protective conductor marked green/yellow in the supply line must be connected to the green/yellow earth ter‐
minal. If conductor lines are used to supply power, the protective earth conductor line must be specially marked. If
it is mounted on insulators, it is sufficient to mark the insulators.
Friction wheel travel drive
The motors are connected in star when they leave the factory. Connect the friction wheel travel drive in accord‐
ance with the wiring diagram.
Ø26
R16
122,5
245
285
Ø20