7 2 11 COMPRESSOR removal
Precautions for exchange of compressor.
Do not allow moisture or debris to get inside refrigerant pipes during work
Procedure for compressor removal.
1 Turn off the power
2 Remove the SERVICE PANEL and RIGHT PANEL
3 Fully close the 3Way valve (gas) and 3Way valve (liquid)
4 Collect the refrigerant from the 3Way valve
Start the following work after completely collecting the refrigerant
Do not reuse the refrigerant that has been collected
COVER - A
Remove the COVER-A,-B and -C
Remove the TERMINAL COVER
- 108 -
Remove the connectors
[R : RED, C(T) : BLACK, S(W) : WHITE]