Niko Swiss Garde 360 Presence KNX UP Instruction Manual

Advertisement

Quick Links

Swiss Garde 360 Presence KNX UP
Item no.
351- 25031
25020N
nv Niko sa, Industriepark West 40, 9100 Sint-Niklaas, Belgium
www.niko.eu, +32 3 778 90 80, support@niko.eu
Instruction Manual
Model
SG360P KNX UP
SG360P KNX UP
EAN
3505100250319
3505100250203
Edition 09-2022
Art.-Nr. 25020N (351-25031)

Advertisement

loading

Summary of Contents for Niko Swiss Garde 360 Presence KNX UP

  • Page 1 Swiss Garde 360 Presence KNX UP Item no. Model 351- 25031 SG360P KNX UP 3505100250319 25020N SG360P KNX UP 3505100250203 nv Niko sa, Industriepark West 40, 9100 Sint-Niklaas, Belgium Edition 09-2022 www.niko.eu, +32 3 778 90 80, support@niko.eu Art.-Nr. 25020N (351-25031)
  • Page 2 Presence detectors 360° KNX for ceiling flush-mounting The family of Swiss Garde 360 Presence KNX UP presence detectors is characterised by the following outstanding features: 1 light output for switching, dimming or scenery selection. • 1 HVAC-channel controls heating, ventilation and air •...
  • Page 3: Installation

    Important notice The presence detectors Swiss Garde 360 Presence KNX UP is suitable for ceiling mounting indoors only (IP20, class II). In case of errors such as continuous light, uncontrolled switching, etc., please consult page 7 „troubleshooting“. Function The presence detector Swiss Garde 360 Presence KNX UP reacts to heat radiation of moving bodies.
  • Page 4: Frontal View

    SG360P KNX UP (351- 25031, 25020N) frontal view rear view bus terminal + (red) bus terminal – (grey) programming button rating plate...
  • Page 5 PIR sensors numbering LED green LED red programming Flashes with each detection glows upon pressing the programming button The PIR sensors 1 2 3 4 can be activated via ETS individually or in groups, using the above numbering scheme. After KNX/EIB bus connection: the detector takes approx.
  • Page 6 Detection range The 360° omnidirectional detection range as well as the dense detection area allow for an optimal function. The range depends on the mounting height as well as the angle of approach (high sensitivity when crossing a switching segment). Since the device registers the temperature differences between the source of heat and the ambient temperature, the detection range may vary depending on site conditions (floor heating, etc.).
  • Page 7 Troubleshooting Error Cause/remedies load doesn`t switch ON • twilight value set to high • check light/luminaire/fuses Detector triggers ON and • check detection area for OFF without reason or potential causes of false light never turns OFF: triggering: animals, heating, etc. may all doing faulty switching •...
  • Page 8: Technical Data

    Technical data nominal voltage: 24V DC (21 - 30V DC) power consumption: 0,4 W PIR- sensors: 4 Pyro detectors sensitivity: adjustable via ETS in 10 steps light measuring: brightness sensor with linear output lux value: value readable (5 - 2000lux, 2 Byte) switiching criteria: motion and brightness detection range:...