Before Use; Inscriptions And Symbols On The Unit - Westfalia 40 68 43 Instruction Manual

Digital multimeter with voltage detector
Table of Contents

Advertisement

Available languages

Available languages

Inscriptions and Symbols on the Unit

10 A
mA/µA/BATT1.5V Input for measuring current up to 200 mA
V/Ω/
/BATT9V Input
COM
LIGHT
HOLD
BATT
~

Before Use

Input for measuring current in the ampere
measuring area of up to 10 A – (AC/DC). In
the range the measuring time must be limited
to a maximum of 10 seconds and the next
measuring should happen no sooner than af-
ter 15 minutes. This measuring area is not
protected with a fuse. If the current is
higher than 10 A, the unit can be de-
stroyed.
(AC/DC), Battery test 1.5 V
for
voltage
resistance measuring, continuity testing, di-
ode testing, battery voltage testing 9 V
Mass Connection
Diode Test Function
Continuity Test Function
Resistance Measuring
Backlight
HOLD Function Button
Battery Voltage Test (1.5 V / 9 V)
AC Voltage, AC Current
DC Voltage, DC Current
Dangerous high voltage between the inputs.
Use extreme caution when taking a meas-
urement. Do not touch the inputs and the
metal tips of the probes.
Attention! Please read the manual carefully!