Rice Lake 350-10 Series Operation Manual

Rice Lake 350-10 Series Operation Manual

Digital wheelchair scales
Hide thumbs Also See for 350-10 Series:

Advertisement

Quick Links

350-10 Series
Digital Wheelchair Scales
Software Version 11525
Operation Manual
Model 350-10-3
Model 350-10-2
Model 350-10-7
Model 350-10-8
August 17, 2022
PN 151640 Rev E

Advertisement

Table of Contents
loading

Summary of Contents for Rice Lake 350-10 Series

  • Page 1 350-10 Series Digital Wheelchair Scales Software Version 11525 Operation Manual Model 350-10-3 Model 350-10-2 Model 350-10-7 Model 350-10-8 August 17, 2022 PN 151640 Rev E...
  • Page 2 All information contained within this publication is, to the best of our knowledge, complete and accurate at the time of publication. Rice Lake Weighing Systems reserves the right to make changes to the technology, features, specifications and design of the equipment without notice.
  • Page 3 Established a revision history; formatted content to match other medical manuals; software version 11525 Table i. Revision Letter History Technical training seminars are available through Rice Lake Weighing Systems. Course descriptions and dates can be viewed at www.ricelake.com/training or obtained by calling 715-234-9171 and asking for the training department.
  • Page 4: Table Of Contents

    6.0 Specifications ............... . . 13 Rice Lake continually offers web-based video training on a growing selection of product-related topics at no cost.
  • Page 5: Introduction

    Introduction Introduction The 350-10 Series digital wheelchair scales are user-friendly, quality scales, designed for safe weighing of handicapped and mobility challenged individuals. Movement compensation technology ensures sound, accurate weighments. The 350-10 Series digital wheelchair scales have roll on ramp access and come in four different configurations: •...
  • Page 6: Safety

    Do not operate or work on this equipment unless this manual has been read and all instructions are understood. Failure to follow the instructions or heed the warnings could result in injury or death. Contact any Rice Lake Weighing Systems dealer for replacement manuals.
  • Page 7: Assembly

    Move the scale into the area where the weighing process will occur. Place the scale on a hard, level surface for the most accurate weighments. Thin carpeting is acceptable, but not recommended. Rice Lake Weighing Systems recommends using two people for lifting the scale and to use proper lifting CAUTION techniques to prevent injury.
  • Page 8 350-10 Series Digital Wheelchair Scales 4. Turn each foot counterclockwise three full rotations to ensure there is adequate clearance between the scale and the floor. 5. Lower the scale base down to the floor carefully. There should be minimal clearance between the scale base and the floor.
  • Page 9: Insert Batteries

    Power Connection An optional AC power adapter can be used when a power outlet is available. Only use power adapters supplied by or purchased from Rice Lake Weighing Systems. The use of a power IMPORTANT adapter not from Rice Lake Weighing Systems voids the warranty.
  • Page 10: Operation

    350-10 Series Digital Wheelchair Scales Operation This section describes the front panel and includes procedures for operation of the scale. Figure 3-1. Front Panel Keypad Key Descriptions The display has 10 front panel keys. Key functions are described in the table below.
  • Page 11: Weighing

    (default is programmed to be 33.0 lb/15.0 kg). 2. Use to adjust the value. Press to start the tare function. The NET annunciator turns on instead ENTER of the GROSS annunciator. © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 12: Using The Body Mass Index (Bmi) Function

    350-10 Series Digital Wheelchair Scales Using the Body Mass Index (BMI) Function Use the following steps in determining the BMI. 3.6.1 LB Mode 1. Ensure that the scale is at zero. 2. Place the patient on the scale to obtain a weight. The LOCK annunciator appears on the display.
  • Page 13: Troubleshooting

    Note: Load cell connection point is located underneath the curved plastic cover of the indicator. Remove four back retaining screws, remove curved back cover to access load cell connection point. Table 3-2. Troubleshooting Table © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 14: Communication

    The unit comes with an RS-232 port that enables weight data to be transmitted to other equipment, such as a computer or printer. The RS-232 cable with DB-9 connector (PN 100719) is available from Rice Lake Weighing Systems. That connection is shown in USB Connection section on the next page.
  • Page 15: Usb Connection

    5. With weight on the scale, press and hold the Print button on the indicator for three seconds. The patient’s weight is sent to the PC. Figure 4-3. Patient Weight Displayed © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 16: Maintenance

    350-10 Series Digital Wheelchair Scales Maintenance The following section provides instructions for maintaining and cleaning the unit. Do not immerse the scale in cleaning or other liquid solutions. IMPORTANT Do not use Isopropyl alcohol or other solutions to clean the indicator display surface.
  • Page 17: Specifications

    Capacity and Graduation 1000 lb x 0.2 lb (453 kg x 0.1 kg) Dimensions Platform Dimensions 48.5 in W x 29.5 in L x 3 in H Certifications and Approvals E113986 © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 18 350-10 Series Digital Wheelchair Scales www.RiceLake.com Visit our website...
  • Page 20 © Rice Lake Weighing Systems Specifications subject to change without notice. 230 W. Coleman St. • Rice Lake, WI 54868 • USA U.S. 800-472-6703 • Canada/Mexico 800-321-6703 • International 715-234-9171 • Europe +31 (0)26 472 1319 August 17, 2022 PN 151640 Rev E...