Fuel Container Protection; Fuse; 5Maintenance - Tech Controllers EU-48 User Manual

Table of Contents

Advertisement

4.6 F
UEL CONTAINER PROTECTION
On the fuel feeder there is an additional temperature measuring sensor. In the event of its signif-
icant increase (above 70
causes pushing the fuel to the combustion chamber. This way the feeder sensor protects against fuel
ignition in the container.
The regulator has a WT 6.3A tubular fuse insert, protecting the network. Using a fuse with a higher
value can cause damage to the existing controller
4.7 F
USE
The regulator has a WT 6.3A tubular fuse insert, protecting the network.
Using a fuse with a higher value can cause damage to the existing controller.
5 M
AINTENANCE
Technical condition of wires should be checked in the ST-48 controller before the heating season
starts and across its duration. One should also check fastening of the controller and clean it from dust
and other dirt. The earthing effectiveness of the engines ( of the CH pump, the HUW pump, the blow-in,
the feeder, the floor pump, the circulation pump)should also be measured.
TECHNICAL DATA
Power supply
Maximum power consumption
Ambient working temperature
Pump max. output load
Valve max. output load
Fan max. output load
Temperature measurement accuracy
Sensor thermal resistance

Fuse

O
C), the alarm is activated; the feeder is activated every 10 minutes, which
230V ±10% /50Hz
11W
5÷50°C
0,5A
0,5A
0,6A
1°C
-30÷99°C
6,3A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EU-48 and is the answer not in the manual?

Questions and answers

Table of Contents