9.1
General
This section describes the repairs that may be performed
on the heaters Thermo Top Z and Thermo Top E and C
when removed. Any further disassembly will void the
warranty. After repairs a functional test must be
performed.
9.1.1 Work on Components after Disassembly
CAUTION
All gaskets located between disassembled components
must always be discarded and replaced.
9.1.1.1 Cleaning
•
All components disassembled must be cleaned.
•
Sealing compound on components must be carefully
and completely removed using suitable means.
9.1.1.2 Visual Inspection
•
Inspect all components for damages (cracks,
deformation, wear, etc.) and replace as required.
•
Inspect connectors and wiring for corrosion, loose
contacts, wrong crimping, etc. and repair as required.
•
Inspect connector terminal for corrosion and contacts
for security.
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
9 Repair