Ocean Optics MFPF100-1 Installation And Operation Manual

Multifrequency phase fluorometer

Advertisement

Quick Links

MultiFrequency Phase Fluorometer
Installation and Operation Manual
Offices:
Ocean Optics, Inc.
830 Douglas Ave., Dunedin, FL, USA 34698
Phone 727.733.2447
Fax
727.733.3962
8 a.m.– 8 p.m. (Mon-Thu), 8 a.m.– 6 p.m. (Fri) EST
Ocean Optics B.V. (Europe)
Ocean Optics B.V. (Europe)
Geograaf 24, 6921 EW DUIVEN, The Netherlands
Phone 31-(0)26-3190500
F ax
31-(0)26-3190505
E-mail:
Info@OceanOptics.com
Info@OceanOpticsBV.com
Orders@OceanOptics.com
TechSupport@OceanOptics.com (Technical support)
Document Number MFPF-00000-000-02-0606
(General sales inquiries)
(European sales inquiries)
(Questions about orders)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MFPF100-1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ocean Optics MFPF100-1

  • Page 1 830 Douglas Ave., Dunedin, FL, USA 34698 Phone 727.733.2447 727.733.3962 8 a.m.– 8 p.m. (Mon-Thu), 8 a.m.– 6 p.m. (Fri) EST Ocean Optics B.V. (Europe) Ocean Optics B.V. (Europe) Geograaf 24, 6921 EW DUIVEN, The Netherlands Phone 31-(0)26-3190500 F ax...
  • Page 2 This manual is sold as part of an order and subject to the condition that it shall not, by way of trade or otherwise, be lent, re-sold, hired out or otherwise circulated without the prior consent of Ocean Optics, Inc. in any form of binding or cover other than that in which it is published.
  • Page 3: Important Safety Notices

    Important Safety Notices WARNINGS Intense UV radiation is emitted from the MFPF LED. Do not look directly at the LED output with the naked eye once the red cap is removed. To verify there is power to the instrument, place a white piece of paper in front of LED 1. 2.
  • Page 4 Important Safety Notices MFPF-00000-000-02-0606...
  • Page 5: Table Of Contents

    Table of Contents Important Safety Notices ....................i About This Manual ......................iii Document Purpose and Intended Audience................iii Document Summary........................iii Product-Related Documentation ....................iii Chapter 1: Introduction ..............1 MFPF System Overview....................1 Applications ........................2 Models ..........................2 Shipment Components ....................
  • Page 6 Table of Contents MFPF-00000-000-02-0606...
  • Page 7: About This Manual

    Detailed instructions for the OOISensors Software are located at: http://www.oceanoptics.com/technical/NEW OOISensors FOXY Manual.pdf Engineering-level documentation is located on our website at Technical → Engineering Docs. You can also access operating instructions for Ocean Optics products from the Software and Technical Resources CD that ships with the product. MFPF-00000-000-02-0606...
  • Page 8 About This Manual MFPF-00000-000-02-0606...
  • Page 9: Chapter 1: Introduction

    The MFPF is used with Ocean Optics’ Fiber Optic Oxygen (FOXY) Sensors and custom probes. FOXY Fiber Optic Oxygen Sensors are low-power, portable devices that offer high sensitivity, reversibility, and stability.
  • Page 10: Applications

    1: Introduction • FOXY (40 kHz) – Ocean Optics’ standard oxygen sensors designed for monitoring oxygen partial pressure in gas and aqueous solutions. FOXY is a fiber optic fluorescence probe with proprietary oxygen-sensing thin-film coating on the tip. • HIOXY (40 kHz) – Designed for monitoring oxygen partial pressure in nonaqueous vapors and solutions.
  • Page 11: Shipment Components

    USB Cable Software and Technical Resources CD Each order ships with the Ocean Optics Software and Resources CD. This disc contains software, operating instructions, and product information for all Ocean Optics software, spectrometers, and MFPF spectroscopic accessories. You need Adobe Acrobat Reader version 6.0 or higher to view these files.
  • Page 12 1: Introduction OOISensor Software OOISensors is an advanced data acquisition and display program that provides a real-time interface to a variety of signal processing functions for users of Windows 95/98/ME/NT/2000/XP. OOISensors software supports USB2000 and USB4000 Spectrometers, and the MFPF unit. Bifurcated Fibers MFPF-00000-000-02-0606...
  • Page 13: Chapter 2: Installation

    OOISensors software – This is a 32-bit, advanced acquisition and display program that provides a realtime interface to display and processing functions for use with Ocean Optics’ oxygen and pH sensors. OOISensors acquires data for use by the MFPF software to convert data into concentration values, and save the data in spectral files and logs.
  • Page 14 2: Installation 2. Start the software installation process. Installing from CD: a. Insert the CD containing the OOISensors and MFPF software. b. Select the drive on your computer with the software CD. c. Double-click on the Setup.exe. The installation wizard appears. Installing from the Web: a.
  • Page 15: Hardware Installation

    Access MFPF software with the icon on your desktop. Access OOISensors software Start | All Programs | Ocean Optics | OOISensors | OOISensors. If you attempt to start OOISensors software without first starting the MFPF software, an error message appears.
  • Page 16 2: Installation 5. Connect one arm (it doesn’t matter which one) of the bifurcated probe fiber to Ch1 LED and the other arm to the Ch1 Detector on front of unit as shown below. MFPF Unit Front Panel 6. Connect power cord from the power supply that came with your MFPF unit from back of unit to an AC outlet.
  • Page 17 1: Introduction MFPF Unit Rear Panel Once you have installed both the hardware and the software, you must configure your system (see Chapter 3: Configuration). MFPF-00000-000-02-0606...
  • Page 18 2: Installation MFPF-00000-000-02-0606...
  • Page 19: Chapter 3: Configuration

    Chapter 3 Configuration Overview Once the software has been installed, the system has been rebooted, and the hardware has been connected to the computer, you must configure the software. Configuring the COM Port with the MFPF Software The MFPF unit uses a USB connection with an emulated RS232 port. Before you are permitted to start the software, you are asked to identify the COM port number of the emulated RS232/USB port.
  • Page 20 3: Configuration Select the Hardware tab. Click Device Manager. 5. Scroll down and expand the Ports (COM & LPT) list item. 6. Note the port number assigned to the CP210x USB to UART device. 7. Ensure that this is the COM port selected on the MFPF software Set Up screen. MFPF-00000-000-02-0606...
  • Page 21: Configuring Ooisensors Software

    3: Configuration 8. Click Done. Configuring OOISensors Software The first time that you run OOISensors, you will be prompted to configure the software for use with your hardware. Follow the steps below to configure OOISensors software. ► Procedure 1. Run OOISensors. If this is the first time you have opened the software, or if the software is not configured yet, the following screen appears: 2.
  • Page 22 3: Configuration Note OOISensors is configured to work with the MFPF unit. However, you can change the OOISensors configuration to work with spectrometers using the Configure | Software menu item. 3. Double-click on the icon on the desktop. The main MFPF screen appears: 4.
  • Page 23 3: Configuration Parameter Setting Frequency kHz 5 kHz – FOSPOR 40 kHz – FOXY and HIOXY APD voltage 110 to 155 V photon-to-electron ratio LED Channel Depends on your experiment Detector Channel Depends on your experiment 5. Select Advanced | Show More Control Panel from the menu bar. The following dialog box appears: 6.
  • Page 24 3: Configuration MFPF-00000-000-02-0606...
  • Page 25: Index

    Index Adobe Acrobat Reader, 3 MFPF applications, 2 configuring the COM port, 11 front panel, 8 models, 2 overview, 1 COM port, 11 rear panel, 9 document OOISensors audience, iii configuring, 13 purpose, iii summary, iii passwords, 3 product-related documentation, iii hardware, 7 recommended equipment, 3 Install...
  • Page 26 Index MFPF-00000-000-02-0606...

This manual is also suitable for:

Mfpf100-2

Table of Contents