System Wiring; Troubleshooting - Redback A 6531 Operating Manual

Programmable touchscreen wallplate
Table of Contents

Advertisement

6.0 SYSTEM WIRING

6.1 RJ45 cabling configuration for connection between the A 6530 or A 6540 series wallplate
Wall Plate and the
A 6505A Serial Hub (586A 'Straight through')
Components are connected using "pin to pin" configuration RJ45 data cabling as shown in fig 6.1. When installing ensure
all connections are verified with a LAN cable tester before switching any system component on.
8
568A
7
6 TX-
Straight Through
5
(both ends)
4
3 TX +
Pins Face Upwards
2 RX-
1 RX+
Failure to follow the correct wiring configuration may result in damage to system components.
6.2 Serial wiring
RS232 Serial wiring from the Redback® A 6505A Serial Hub to the Redback® A 6510 or the Redback® A 6515
The RS232 control cabling requires only two connections from the output of the A 6505A Serial Hub to the input connec-
tor of the A 6510 or A 6515. The TX pin of the A 6505A is connected to the RX connection of the A 6510 or A 6515, and
the GND terminals are connected together.
RS232 Serial wiring from Third Party Device to Redback® A 6510 or the Redback® A 6515
The RS232 control cabling requires only two connections from the output of the third party device to the input connector
of the A 6510 or A 6515. The TX pin of the output device is connected to the RX connection of the A 6510 or A 6515,
and the GND terminals are connected together.
RS485 Serial wiring from the Redback® A 6505A Serial Hub to the Redback® A 6510 or the Redback® A 6515
The RS485 control cabling requires three connections from the output of the A 6505A Serial Hub to the input connector
of the A 6510 or A 6515. The "A" connection of the A 6505A is connected to the "A" connection of the A 6510 or A
6515, the "B" connection of the A 6505A is connected to the "B" connection of the A 6510 or A 6515 and the GND
terminals are connected together.
RS485 Serial wiring from Third Party Device to Redback® A 6510 or the Redback® A 6515
The RS485 control cabling requires three connections from the output of the third party device to the input connector of
the A 6510 or A 6515. The "A" pin of the output device is connected to the "A" connection of the A 6510 or A 6515,
the "B" pin of the output device is connected to the "B" connection of the A 6510 or A 6515, and the GND terminals are
connected together.
7.0 TROUBLE SHOOTING
SYMPTOMS
A 6530 or A 6540 series wallplate wall plate not powering up
A 6507/6510/A 6512/A 6514 or A 6515 not
accepting serial codes
IR transmission not working
www.redbackaudio.com.au
Redback® A 6500A Programmable Control System
Redback® A 6500A Programmable Control System
Redback® Programmable Control System
Fig 6.1
REMEDIES
Check DIP switches 1-3 on these units are set correctly and/or
check wiring
Check IR led wiring/check DIP switch 1 on A 6505A
Redback® Proudly Made In Australia 23
Check Cat5e connection to
A 6505A/07/10/12/14/15
1 TX+
2 TX-
3 RX +
4
5
6 RX-
7
8