Download Print this page

Cal-Royal ES1433 Series Installation Instructions page 2

Electric strike

Advertisement

Installation Instructions
( 1)
Measure latch position.
(4)
Cut hole using template.
Caution:
Proper gap must be reserved between the strike keeper and latch bolt to prevent failure
of solenoid valve.
Using the Trim Plate
12 / 24 VDC Plug-In Wiring
For 12VDC Operation:
' p.--.1.apL---1
Black
'
(Polarity Insensitive)
CAL-ROYAL
P R O D U C T S,
I N C. U.S. A.
(2)
(5)
1 1 1 1 6" (
Install the mounting tabs.
In case of over-cutting,
use the enclosed trim
plate to cover up any
errors.
c ; �
:�
- � �� : ce
-�
1
1
..__-+· � --i--- + �
· · -------·
Mark latch position line.
1 7tn
)
tn
Installing the Crimp Connectors:
Crimp connectors are
provided to make wiring
connections easier and
more reliable. To install the connectors:
1. Insert the wires into the connector.
2. Use a crimping tool or pliers to evenly press down
on the head of the connector.
For 24VDC Operation:
'P---�----'I
(Polarity Insensitive)
(3)
Attach sticker template to
marked centerline.
(6)
Connect the wires using the crimp
connectors, then test the strike,
ensure to give it correct voltage.
C�n-1��
-�:� '. ce
1
--+-
Black
· · -------·
.._ __ 4:..---
DWG # ELG8009, P/2 , 20220407
-r-:::7
L.:.::J
+

Advertisement