Panasonic AG-DV2500P Service Manual page 278

Hide thumbs Also See for AG-DV2500P:
Table of Contents

Advertisement

Measuring
No.
Item
instruments &
Input signals
4
FS PLL 48
Frequency
kHz adjust-
counter
ment
No input
5
FS PLL
Frequency
44.1 kHz
counter
adjustment
No input
6
FS PLL 32
No input.
kHz adjust-
ment
7
27 MHz VCO
Frequency
center
counter
frequency
No input
adjustment
Measuring point
Mode
Adjustment parts (
Adjustment level (
EE
TP4 (FS PLL)
ADJUST
GND: TP1 (GND)
MENU, 110. FS
[Rewrite board]
PLL 48 kHz
[PLAY] and [STOP]
buttons
12.288 MHz
MHz
EE
TP4 (FS PLL)
ADJUST
GND: TP1 (GND)
MENU, 111.
[Rewrite board]
FS PLL
[PLAY] and [STOP]
44.1 kHz
buttons
11.2896 MHz
MHz
EE
Monitor display
ADJUST
[PLAY] and [STOP]
MENU,112. FS
buttons
PLL 32 kHz
Value adjusted in No.
110, "FS PLL 48 kHz"
in item 4 above.
EE
TP7 (MAIN VCO)
ADJUST
GND: TP1 (GND)
MENU,113.
[Rewrite board]
27 MHz VCO
[PLAY] and [STOP]
buttons
13.5 MHz
(
)
)
Adjustment procedure
)
(1)Select ADJUST MENU No. 110, "FS PLL 48
kHz".
(2)Press the [SET] button to measure frequency.
(3)Adjust the frequency to the specified value.
(4)Press the [SET] button to store the adjustment
data.
0.1
(1)Select ADJUST MENU No. 111, "FS PLL 44.1
kHz".
(2)Press the [SET] button to measure frequency.
(3)Adjust the frequency to the specified value.
(4)Press the [SET] button to store the adjustment
0.1
data.
(1)Select ADJUST MENU No. 112, "FS PLL 32
kHz".
(2)Press the [SET] button to measure frequency.
(3)Adjust to the same value as the FS PLL 48
kHz adjustment value. (Setting range: 0 to 255)
(4)Press the [SET] button to store the adjustment
data.
(1)Select ADJUST MENU No. 113, "27 MHz VCO".
(2)Press the [SET] button to measure frequency.
(3)Adjust the frequency to the specified value.
(4)Press the [SET] button to store the adjustment
data.
0.1 MHz
3-7