1.8.3 VTR 1 menu
Item
REC REPEAT
FOOT SW LEVEL
MIC REC CH
ID 422 (H)
ID 422 (L)
FF/REW SPEED
DV DF MASK (PAL only)
1.8.4 VTR 2 menu
Item
LONG PAUSE
REC MODE
LP WARNING
TEST SIGNAL
TEMP THRESHOLD
BATT. SHUT DOWN
BATT. ALARM
1-8
OFF
No repeat recording
2
Repeat recording 2 times
12
Repeat recording 12 times
ON
Full repeat recording
LEVEL1
Possible from any mode
LEVEL2
Possible only from STOP or REC PAUSE mode
NORMAL
Record input signal from connected MIC only on CH2 (CH4 : during A.DUB mode)
CH1-MIX
[No recording mode]. Do not record input signal from connected MIC on CH1/CH2
(No recording on CH3+4 during A.DUB)
CH2-MIX
Record input signal from connected MIC on CH1/CH2 (CH3/CH4 during A.DUB)
F0
High Device ID (00~FF). First bit is fixed at PAL1, NTSC0
4E
Low Device ID (00~FF)
x50
Maximum FF/REW speed is regulated to x50
x75
Maximum FF/REW speed is regulated to x75
x100
Maximum FF/REW speed is regulated to x100
MAX
No maximum FF/REW speed regulation
OFF
"1" is recorded as per format
ON
"0" is always recorded
Table 1.8.3 VTR 1 Menu Setting Item List
OFF
Disables long pause function
ON
Enables long pause function
SP
SP recording
LP
LP recording (Do not change since performance cannot be guaranteed)
OFF
LP INH not displayed (Enables playback with LP mode) (Do not change since
performance cannot be guaranteed)
ON
LP INH displayed (Disables playback with LP mode)
OFF
Output color bars only. Do not output any other TEST signals.
ON
Use BARS button of a attached wireless controller reception to trigger output TEST
signal, rotating in this order:
Color bars
track)
Multi burst (Y signal only)
Red
Black burst
220
Threshold of rising temperature warning display, 00~255 (220 [DCh] = internal
temperature approx. 60°C). Refer to item "TEMP" in table 1.8.7 (1)
10.5
Voltage value to carry out power OFF operation (Set at OFF, 10.0~12.0 in
increments of 0.1)
11.0
Voltage value to trigger display of battery alarm warning (Set at 10.0~12.0 in
increments of 0.1)
Table 1.8.4 VTR 2 Menu Setting Item List
Parameter
is default setting when shipped from factory.
Parameter
Color bars (rotate per track)
Multi burst (Y and C signals)
is default setting when shipped from factory.
Grayscale
Grayscale (rotate per