5. Selecting the Mode2 for Service-related
Selecting Each Mode.
5.1. Starting up
While the power is on, hold down buttons "POWER" and "ENTER" for at least 3 seconds.
(1) "LEGO Log Capture Mode" is displayed.
(2) First release the "ENTER" button, then the "POWER" button.
5-1. LEGO Log Capture mode
• Acquires the Network Module log.
• The log is deleted when the Network Module is deleted.
If an error occurs, it is acquired without turning off the power of this unit.
• The log can be copied to a writable USB flash drive.
It can also be sent to a server if this unit is connected to the Internet.
• The log is stored in the root folder of the USB flash drive with the name "logs-<friendlyname>-
<number>.tar.gz".
<friendlyname> indicates the friendly name and <number> indicates the sequence number.
Previous logs on the USB flash drive are not overwritten. The log is encrypted.
5-1.1. Starting up
While the power is on, hold down buttons "POWER" and "ENTER" for at least 3 seconds.
(1) "LEGO Log Capture Mode" is displayed.
(2) First release the "ENTER" button, then the "POWER" button.
(3) Press the "ENTER" button to start up.
5-1.2. If the USB flash drive is connected after starting the unit
(1) The log is written to the USB flash drive and "Storing Logs..." is displayed.
Press the "ENTER" button to send the log to the server too.
(2) When a log package is saved to a USB flash drive, "USB SUCCESS" appears in the display for 5 sec-
onds, regardless of whether the upload to the server was successful.
(3) When saving of the log package fails, "USB FAILED" appears in the display for 5 seconds, regardless
of whether the upload to the server was successful.
5-1.3. When the USB flash drive is not connected after startup, and this
unit is connected to the Internet.
(1) The log is sent to the server and the display shows "Storing Logs..." for 5 seconds.
(2) When the log package is uploaded, the ticket numbers "Ticket No:XXXXX" are displayed until RC
or the "Enter" or "BACK" button of this machine is pressed.
(3) If the log package upload fails, "FAILED" is displayed for 5 seconds.