Specifications - NewMar Phase Three PT-7 Installation & Operation Manual

Table of Contents

Advertisement

circuit that produces an extremely well-filtered d.c. output. Therefore it is able to power
virtually any d.c. powered device (within the unit's rating) without the battery attached
in-line (if, for instance, the battery must be removed for any purpose and a.c. is still
available). All but the most sensitive d.c. powered electronic devices will function as
normally as if powered by a battery. When using the PT-7 as a regulated power supply
without battery in-line, place the Charger Cycle select switch in the "FLOAT" position for
maximum regulation.
V)

SPECIFICATIONS

Model:
Input VAC (50-60 Hz.):
Input Amps @ Full Load:
@ 115 VAC
@ 230 VAC
Output Voltage (Nominal VDC):
Output Amps (Continuous):
Output Banks:
Battery Capacity (Amp-Hours):
Weight (Lbs./Kg.):
Compliances: Ignition protected per USCG CFR 183.410, Carries the CE Mark
Temperature Rating: -10°C to +60°C; Derate linearly from 100% @ 50°C to 60% @ 60°C
Nominal Output Voltages at Gel/Flooded Switch Settings:
Setting
Flooded/AGM
Gel-Cell
Protection: Input/Output Fuses, Current Limiting, Thermal Protection, Forced Air Cooling, Drip Shield
Case Dimensions (Inches):
12
U.S.A. HEADQUARTERS
P.O. Box 1306, Newport Beach, CA 92663
Phone: 714-751-0488 Fax: 714-957-1621
E-Mail: sales@newmarpower.com
PT-7
82-132 or 164-264
2
1
12
7
2
14-70
3.2/1.5
Charge
Float
@ 50 % load
@ .5 amp load
14.0-14.2V d.c. 13.4V d.c
13.8-14.0V d.c. 13.6V d.c.
E