Condition
C) Front panel status indicator is
not lit and there is no indication
of charger output.
D) Charger repeatedly trips
input circuit breaker with no
batteries connected.
E) High output voltage
measured across output
terminals.
If a problem with your charger persists after you have applied the above-outlined solutions, or if you have any questions about the
installation and proper operation of your charger, please contact NEWMAR's Technical Services Manager:
Phone: 714-751-0488 — From the hours of 7:00 A.M. to 4:30 P.M. weekdays, P.S.T.
Fax: 714-957-1621 — Anytime
E-Mail: techservice@newmarpower.com — Anytime
We will respond no later than the following business day and are always happy to consult with you to resolve any problem you may
have. If it appears the charger must be returned to the factory for repair we will issue a Return Materials Authorization at that time.

VII) SPECIFICATIONS

Model
VAC±10%
50-60 Hz
PT-24-45W
230
PT-32-25W
115
* P.L. = Maximum amps at Power Limit
** F.V. = Maximum amps at Full (Float) Voltage—See OUTPUT VOLTAGES below
CASE SIZE
Inches
H x W x D
13.8 x 9.8 x 5.0
Add 1.27" (3.2 cm) to height and 1.1" (2.8 cm) to depth with drip shield installed.
OUTPUT VOLTAGES
14
P.O. Box 1306, Newport Beach, California 92663 • Phone: 714-751-0488 • Fax: 714-957-1621 • E-Mail: techservice@newmarpower.com
Possible Cause
1) Charger is not receiving A.C. input
voltage or is connected to incorrect A.C.
voltage
2) Extreme overheating of charger has
caused thermal switch to temporarily shut off
A.C. input.
3) Reverse polarity connection or direct short
across output terminals has caused failure.
Internal Short
Batteries not connected to charger
Input
Max
Max Amps
Amps
@ P.L.*
8
45
15
27
Centimeters
H x W x D
35.0 x 24.9 x 12.7
www.newmarpower.com
Solution
1) Confirm charger model is compatible with 115V or
230V A.C. voltage being applied. Check for proper
input voltage with A.C. voltmeter. Check input
wiring connections.
2) If charger is warm to the touch while the Status
Indicator is extinguished, refer to section IV-C, item 1,
which explains the two types of thermal shutdown
indications and solutions.
3) Refer to factory contact information below.
Refer to factory contact information below.
Check for tight connection of charging leads to
batteries.
Output
Battery
Capacity
Max Amps
Banks
(Amp-Hour)
@ F.V.**
38
3
90-450
24
3
50-300
Weight
Lbs.
Kg.
12.2
5.6
12.2
5.6