en Troubleshooting

Information on display panel

Fault
Special salt refill indicator
lights up.
Refill indicator for special
salt does not light up.
Refill indicator for rinse aid
lights up.
Refill indicator for rinse aid
does not light up.

Malfunctions

Fault
Water is left in the appliance
at the end of the pro-
gramme.
Appliance cannot be
switched on or operated.
Appliance does not start.
58
Cause
Insufficient special salt.
Sensor does not detect spe-
cial salt tablets.
Water softening system is
switched off.
Insufficient rinse aid.
Rinse aid system is switched
off.
Cause
Filter system or area under
the filters is blocked.
Programme has not yet
ended.
Software update is taking
place.
Appliance functions have
failed.
The mains fuse has tripped.
Mains cable is not inserted.
Appliance door is not closed
properly.
Troubleshooting
Add "Special salt" → Page 28.
Do not use special salt tablets.
Setting the water softening system
Add "Rinse aid" → Page 30.
1.
Set the amount of rinse aid to be
2.
dispensed.
→ "Setting the amount of rinse aid",
Page 30
Set the amount of rinse aid to be
dispensed.
Troubleshooting
Clean the "Filters" → Page 44.
1.
Clean the "Wastewater pump"
2.
→ Page 61.
Wait until the programme ends or
cancel the programme with Reset.
→ "Terminate programme",
Page 37
Wait until the software update has
finished.
Pull out the mains plug or switch off
1.
the fuse.
Wait at least 2 minutes.
2.
Connect the appliance to the power
3.
supply.
Switch the appliance on.
4.
Check the relevant fuse.
Check whether the socket works.
1.
Check whether the mains cable is
2.
properly inserted in the socket and
on the rear of the appliance.
Close the appliance door.