Installing the FLC-706 in the COT Shelf

lncoming calls

Verify incoming calls for both B channels, for example, calls from the LT to the NT1 (refer to
1
To test an incoming B1 voice call:
a
draw dial tone from another ISDN or POTS circuit
b
dial the ISDN B1 voice circuit number
c
verify that the number you called is displayed (when answered)
verify that the number from which you called is displayed as the originating number
2
Hold up the B1 voice circuit, then switch to the B2 data circuit.
3
Originate an outgoing call on the B2 data circuit using another ISDN data circuit and call the B2 data circuit
under test. Then, perform the BER test.
4
Drop the B2 data line after the B2 test is completed. Then drop the B1 voice line.
5
Return all circuits to normal.
6
January 6, 2003
SCP-FLC706-011-03H
Figure 1 on page
2):