Installation

Listed below is the operating procedure to place your bottom probes on the predefined positions in Data
mode.
[ Operating procedure ]
Use your mouse to select " Tool" > " Mode Setting" > " Data mode" in order.
1.
Move to Bottom tools and select " Bottom probe" from the Tabs.
2.
3.
Click [Verify the positions for Bottom tools] button, and it displays Fig.62.You should specify the
reference point for the bottom probes. Make sure that the pc board is placed on the tester and
depress [TEST START] SW on the operation panel.
4.
The JOG screen (Fig. 62) appears on the display and Probe 4 moves to the front. Use the keypad
arrow keys on the operation panel to set the target mark to the bottom reference point for your
bottom probes and depress [ENTER] SW.
[Fig.61] Bottom probe
[Fig.61] Bottom probe
[Fig.62] JOG screen