Installation; Log Set Installation; Installing Log Set Into Existing Fireplace - Napoleon Woodland HEFI27H Installation And Operating Instructions Manual

Electric logset insert
Table of Contents

Advertisement

8

3.0 INSTALLATION

EN
RISK OF FIRE! THE POWER CORD MUST NOT BE PINCHED AGAINST A SHARP EDGE. SECURE CORD TO AVOID
TRIPPING OR SNAGGING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY. DO NOT RUN
CORD UNDER CARPETING. DO NOT COVER CORD WITH THROW RUGS, RUNNERS OR THE LIKE. ARRANGE CORD
RISK OF FIRE! TO PREVENT A POSSIBLE FIRE, DO NOT BLOCK AIR INTAKE OR EXHAUST IN ANY MANNER. DO NOT
THIS ELECTRIC APPLIANCE IS TESTED AND LISTED FOR USE ONLY WITH THE APPROVED OPTIONAL ACCESSORIES.
USE OF OPTIONAL ACCESSORIES NOT SPECIFICALLY TESTED FOR THIS ELECTRIC APPLIANCE COULD VOID THE
IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT
CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. DO NOT STORE OR USE GASOLINE OR OTHER
THIS APPLIANCE IS HEAVY. IT IS HIGHLY RECOMMENDED THAT TWO PEOPLE INSTALL THIS APPLIANCE.
HEATER VENTS ON THE ELECTRIC APPLIANCE CANNOT, IN ANY WAY, BE COVERED AS IT MAY CREATE A FIRE
NOTE: Follow all National and local electrical codes.
3.1

LOG SET INSTALLATION

The log set can be installed in any location. It is suggested to install the log set into an existing fireplace or a
wood mantel for aesthetic purposes.
Select a suitable location that is not susceptible to moisture and is away from drapes, furniture and high
traffic areas.

3.1.1 INSTALLING LOG SET INTO EXISTING FIREPLACE

The log set insert must be installed in an opening with the minimum cavity sizes shown below:
MINIMUM FIREPLACE CAVITY SIZE
LOG SET
NEFI24H
NEFI27H
NOTE: Seal all chimney drafts with non-combustible materials to prevent any chimney debris from
falling onto the log set. Cap the top of the chimney flue to prevent rain from entering.
Plug the log set into an outlet which has a 15Amp, 120V rating. If it is necessary to hard wire the log set see
"HARD WIRING INSTALLATION" section.
WARNING: Due to the high temperatures, do not use existing fireplace doors which close or seal off
the log set. If installed behind any fireplace door, allow heat to be exhausted. If using existing screens,
the screen must provide adequate airflow in front of the log set.
W415-1461 / C / 08.04.16
AWAY FROM TRAFFIC AREAS AND WHERE IT WILL NOT BE TRIPPED OVER.
USE ON SOFT SURFACES WHERE OPENINGS MAY BECOME BLOCKED.
RISK OF FIRE! DO NOT BLOW OR PLACE INSULATION AGAINST THE APPLIANCE.
WARRANTY AND/OR RESULT IN A SAFETY HAZARD.
FLAMMABLE VAPORS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
DO NOT RUN THE POWER CORD HORIZONTALLY, DIRECTLY BELOW THE APPLIANCE.
HEIGHT
WIDTH
A
B
15"
24"
(381mm)
(610mm)
16"
27 1/2"
(406mm)
(698mm)
WARNING
!
HAZARD.
Do not install the log set
into a cavity smaller than
DEPTH
that referenced in the
C
table.
14"
(356mm)
14"
(356mm)
68.5A
A
B
C

Advertisement

Table of Contents
loading

This manual is also suitable for:

Woodland nefi24h

Table of Contents