Table of Contents

Advertisement

Available languages

Available languages

Quick Links

NATURAL GAS MODELS:
PROPANE GAS MODELS:
SAFETY INFORMATION
WARNING
!
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
- Do not store or use gasoline or other
fl ammable vapors and liquids in the vicinity of
this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call
the fi re department.
- Installation and service must be
performed by a qualifi ed installer, service
agency, or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless
a certifi ed kit is used.
INSTALLER:
Leave this manual with the appliance
CONSUMER:
Retain this manual for future reference
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030
$10.00
ADD PRODUCT CODE HERE (TRADE GOTHIC LT STD FONT)
B35NL
B35PL
Phone 1 (866) 820-8686 • www.napoleon.com • hearth@napoleon.com
INSTALLATION AND
ADD MANUAL TITLE
OPERATION MANUAL
CERTIFIED TO THE CANADIAN AND AMERICAN NATIONAL STANDARDS:
CSA 2.22 AND ANSI Z21.50 FOR VENTED DECORATIVE GAS APPLIANCES
IF INSTALLATION + OPERATION, ADD SERIAL
CSA /
INTERTEK
BARCODE LABEL ON THE OWNER'S MANUAL"
LOGO
Product Name / Code
(MUST use title from Price Book)
Log Burner Assembly
ADD ____ ILLUSTRATED
ADD PRODUCT IMAGE
FOR INDOOR USE ONLY
NUMBER LABEL HERE
IF SEPARATE MANUALS, ADD "PLACE
ENGLISH
FRENCH PG. 13
HDX35
W415-2743 / 08.26.19

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon HDX35

  • Page 1 IF SEPARATE MANUALS, ADD “PLACE INTERTEK BARCODE LABEL ON THE OWNER’S MANUAL” LOGO Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone 1 (866) 820-8686 • www.napoleon.com • hearth@napoleon.com W415-2743 / 08.26.19 $10.00...
  • Page 2: Table Of Contents

    For more information, go to www.P65Warnings.ca.gov. 1.0 general information This burner and log assembly are approved for use in the HDX35 gas appliance only. They are not approved for use as a stand alone appliance or in conjunction with any other appliance.
  • Page 3: Installation

    installation air adjustment rod installation Tilt the burner forward lining the air adjustment cable with the hole in the air control rod. burner assembly Attach the burner assembly to the fi rebox base with the 2 screws supplied. W415-2743 / 08.26.19...
  • Page 4: Bulkheads

    installation 2.4 bulkheads note: Bulkhead covers need to be removed. Connect the main burner gas fl ex line and the pilot line to the gas fi ttings on the bulkheads Main located under the valve access opening.Care Burner Gas must be taken to ensure the pilot line isn’t Connection damaged and ensuring gas tight connections are made.
  • Page 5: Hearth Panel Installation

    installation hearth panel installation note: It is recommended to remove the grate assembly prior to panel installation. Hearth fl oor panel is shipped separate from appliance and are included with the mandatory brick panel kits. Due to the brittle material of the panels, care must be taken not to bend or force them into place. When shipped, the hearth panels range in varying shades of Sandstone / New Port.
  • Page 6: Hearth Log & Log Placement

    installation hearth log & log placement note: All logs are stamped with a part number. Push the rear log (W135-0594) back Place the nochtes in the bottom of the fl ush against the rear panel. front right log (W135-0598) over the right grate posts.
  • Page 7: Charcoal Lumps

    installation charcoal lumps WARNING • Do not block or close off the burner ports. Blocked ports can cause an incorrect fl ame pattern, carbon deposits and delayed ignition. • When supplied, charcoal embers, charcoal lumps and vermiculite are not to be placed on the burner. Place the lumps in front of the logs in a realistic manner taking care not to block or close off any of the burner ports.
  • Page 8: Adjustment

    3.0 adjustment fl ame characteristics It’s important to periodically perform a visual check of the pilot and burner flames. Compare them to the illustration provided. If any flames appear abnormal, 3/8” - 1/2” call a service person. (9.5mm - 12.7mm) Flame must envelop upper 3/8"...
  • Page 9: Replacement Parts

    4.0 replacement parts WARNING • Failure to position the parts in accordance with this manual or failure to use only parts specifi cally approved with this appliance may result in property damage or personal injury. Contact your dealer for questions concerning prices and policies on replacement parts. Normally, all parts can be ordered through your Authorized dealer / distributor.
  • Page 10: B35Nl Log Burner

    replacement parts W415-2743 / 08.26.19...
  • Page 11 6.0 notes W415-2743 / 08.26.19...
  • Page 12 NAPOLEON CELEBRATING OVER 40 YEARS OF HOME COMFORT PRODUCTS 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 103 Miller Drive, Crittenden, Kentucky, USA 41030 Phone: 1-866-820-8686...
  • Page 13 IF SEPARATE MANUALS, ADD “PLACE LOGO BARCODE LABEL ON THE OWNER’S MANUAL” Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Téléphone 1(866)820-8686 • www.napoleon.com • hearth@napoleon.com W415-2743 / 08.26.19...
  • Page 14: 1.0 Information Générale

    Pour de plus amples renseignements, visitez le www.P65Warnings.ca.gov. 1.0 information générale Ce brûleur et cet assemblage de bûches sont approuvés pour utilisation dans l’appareil au gaz HDX35 seulement. Ils ne sont pas approuvés pour utilisation comme appareil autonome ou avec n’importe quel autre appareil.
  • Page 15: Installation De La Tige De Réglage De L'air

    installation installation de la tige de réglage de l’air Inclinez le brûleur avant alignant le câble de réglage d’air avec le trou dans la tige de contrôle d’air. assemblage de brûleur Fixez le brûleur à la base de l’appareil avec les 2 vis fournies.
  • Page 16: Raccords

    installation 2.4 raccords note: Les couvercles des raccords doivent être retirés. Branchez les conduits de gaz fl exibles et la conduit de la veilleuse aux raccords de gaz Main Raccord de situés en dessous de l’ouverture d’accès de Burner Gas la soupape.
  • Page 17: Installation Des Panneaux De Plancher

    installation installation des panneaux de plancher note: Nous vous suggérons d’enlever l’ensemble de la grillage avant l’installation du panneau. Le panneau de plancher sont expédiés séparément de l’appareil et ils sont inclus avec l’assemblage du brûleur et les bûches. En raison de la fragilité des panneaux, prenez grand soin de ne pas courbez ou forcer les panneaux pour les mettre en place.
  • Page 18: Disposition Des Bûches

    installation disposition des bûches note: Tous les bûches sont estampillés avec un numéro de pièce. Poussez la bûche arrière (W135-0594) Placez les encoches dans l’inférieure de arrière à plat contre le panneau arrière. la bûche avant droite (W135-0598) sur les grillage droite. Placez le bûche croisé...
  • Page 19: Morceaux De Charbon

    installation morceaux de charbon AVERTISSEMENT • Obstruez pas ni fermer les orifi ces du brûleur. Le blocage des orifi ces du brûleur peut créer une fl amme irrégulière, des dépôts de carbone et un retard d’allumage. • Si équipée, les braises de charbon de bois, les morceaux de charbon et la vermiculite ne doivent pas être placés sur le brûleur.
  • Page 20: Réglages

    3.0 réglages caractéristiques de la fl amme Il est important d’effectuer périodiquement une inspection visuelle de la flamme de la veilleuse et du brûleur. Comparez-les à ces illustrations. Si des flammes paraissent anormales, contactez un 3/8” - 1/2” technicien de service. (9.5mm - 12.7mm) La flamme doit envelopper la sonde de flamme de...
  • Page 21: Pièces De Rechange

    4.0 pièces de rechange AVERTISSEMENT • Omettre de positionner les pièces conformément à ce manuel ou d’utiliser uniquement des pièces spécifi quement approuvées pour cet appareil peut causer des dommages matériels ou des blessures corporelles. Contactez votre détaillant pour les questions concernant les prix et la disponibilité des pièces de remplace- ment.
  • Page 22 pièces de rechange W415-2743 / 08.26.19...
  • Page 23 6.0 notes W415-2743 / 08.26.19...
  • Page 24 À À À T IO ODUITS CONFORT 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 103 Miller Drive, Crittenden, Kentucky, USA 41030 Téléphone: 1-866-820-8686 napoleon.com...

Table of Contents