2.3

bulkheads

note:
Bulkhead covers need to be removed before
beginning installation.
A.
Connect the main burner gas fl ex line and the
pilot line to the gas fi ttings on the bulkheads
located under the valve access opening. Care
must be taken to ensure the pilot line is not
damaged and gas tight connections are made.
B.
Connect the pilot electrode lead to the
bulkhead, matching the 3/16" fl ag with the
3/16" bulkhead spade. Do the same with
the 1/4" spark lead, matching it with the 1/4"
bulkhead spade.
note:
Ensure the venturi tube is over the orifi ce before
lighting.
C.
Check for gas leaks by brushing on a soap
and water solution. Do not use open fl ame.
D.
After leak test has been performed, re-install
access panel with gasket.