PVA-811X Power Vent Adaptor Kit Installation Instructions
These instructions are to be used in conjunction with those for the GPV and your appliance.
This information supercedes that your appliance installation manual.
You will need:
Included in PVA-811X:
W500-0551
W750-0445
W010-3440
W175-0386
W175-0001
W175-0013
W410-0029
W410-0017
W280-0202
W280-0201
INSTALLATION TIP: ACCESS TO THE CONTROL HOUSING IS NECESSARY TO COMPLETE THIS INSTALLATION!
IT IS RECOMMENCED TO INSTALL THE GPV CONTROL INTO THE APPLIANCE HOUSING PRIOR TO INSTALLING
THE APPLIANCE. ACCESS TO CONTROLS THROUGH THE FIREBOX IS LIMITED ONCE THE APPLIANCE HAS BEEN
INSTALLED.
The HD81 uses 8" (203.2mm) and 10" (254mm) fl exible venting.
When installing the GPV for use with the HD81, the 4"/7" reducer
(W175-0310) is required. The reducer must be properly secured
and sealed to the appliance using high temperature sealant W573-
0007 Mill Pac (not supplied)before continuing with vent installation.
The 5' (1.5m) section of stainless steel fl ex liner (supplied) must
be secured and sealed to the reducer using a minimum of 3
screws and high temperature sealant W573-0007 Mill Pac (not
supplied). Install 3 spacers, as illustrated below, ensure they are
evenly spaced along the liner. Use 4" (101.6mm) and 7" (177.8mm)
couplers to connect additional vent lengths up to 65 feet (19.8m).
WARNING: The 5' (1.5m) of stainless steel fl ex liner (supplied)
must be installed directly off the appliance.
INSTALLER: Leave these instructions with the appliance.
CONSUMER: Retain these instructions for future reference.
Dilution plate
Wire harness
Firestop assembly
Connector, reducer 8"/11" to 4"/7"
Coupler, 4"
Coupler, 7"
Liner, 5' stainless steel
Flex line, 7"
Frame, firestop A
Frame, firestop B
W415-4076 / A / 03.08.22

Advertisement

loading

Summary of Contents for Napoleon PVA-811X

  • Page 1 PVA-811X Power Vent Adaptor Kit Installation Instructions INSTALLER: Leave these instructions with the appliance. These instructions are to be used in conjunction with those for the GPV and your appliance. This information supercedes that your appliance installation manual. CONSUMER: Retain these instructions for future reference.
  • Page 2: Terminal Installation

    TERMINAL INSTALLATION REFER TO GPV INSTALLATION INSTRUCTIONS FIRESTOP VENTING INSTALLATION THE FIRESTOP ASSEMBLY MUST BE INSTALLED WITH THE VENT SHIELD TO THE TOP. DO NOT FILL THE CAVITY BETWEEN THE PIPE AND THE FRAMING WITH ANY TYPE OF MATERIAL. TERMINALS MUST NOT BE RECESSED INTO A WALL OR SIDING MORE THAN THE DEPTH OF THE RETURN FLANGE OF THE MOUNTING PLATE.
  • Page 3: Vent Lengths

    DO NOT ALLOW THE INNER FLEX PIPE TO BUNCH UP ON THE HORIZONTAL OR VERTICAL RUNS AND ELBOWS. KEEP IT PULLED TIGHT. SPACERS ARE ATTACHED TO THE INNER FLEX PIPE AT PREDETERMINED INTERVALS TO MAINTAIN AS EVEN AIR GAP TO THE OUTER FLEX PIPE.
  • Page 4 MULTI ELBOW Multi-elbow installations are possible up to a maximum of six 90°. ELBOWS V1+V2+V3+ V1+V2+V3+ H1+H2+H3 H1+H2+H3 65 FEET 10 FEET SIX 90° DOWNWARD VERTICAL VENTING MAX D H1+H2+V H1+H2+V ELBOWS 65 FEET 10 FEET 8 FEET SIX 90° note: If the Continuous Pilot Ignition feature is activated, the power vent blower will also activate.
  • Page 5 Control Board Installation 1. Identify all wires to avoid confusion when reinstalling the control board. Disconnect all wires from control board. note: Wire connections will only fi t in designated locations. 2. Using a fl at head screwdriver carefully release the 4 tabs (2 per side) to remove the top cover from the control board. note: It may be easier to remove the control board from the appliance.
  • Page 6 1. Remove the jumper (JP1) from the control board. (This activates the power vent function). 2. Replace the control board cover and all wire harness connections except for the power cord (x1), it will be replaced with the new wire harness (provided). 3.
  • Page 7 Instructions d’Installation de la Terminaison Mécanique PVA-811X INSTALLATEUR: Laissez ces instructions avec l’appareil. Ces instructions doivent être utilisées conjointement avec celles du GPV et votre appareil. Cet information remplacent les instructions d’installation dans le manuel de votre appareil. PROPRIÉTAIRE: Conservez ce manuel pour consultation ultérieure.
  • Page 8 INSTALLATION DE LA TERMINAISON RÉFÉREZ-VOUS AUX INSTRUCTIONS D’INSTALLATION DU GVP. INSTALLATION DE L’ÉVACUATION ET DE L’ESPACEUR COUPE-FEU L’ESPACEUR COUPE-FEU DOIT ÊTRE INSTALLÉ AVEC L’ÉCRAN PROTECTEUR ORIENTÉ VERS LE HAUT. NE REMPLISSEZ L’ESPACE ENTRE LE CONDUIT D’ÉVENT ET LE MANCHON DE L’ESPACEUR COUPE-FEU AVEC AUCUN TYPE DE MATÉRIAU.
  • Page 9 NE LAISSEZ PAS LA GAINE FLEXIBLE INTÉRIEURE SE TASSER CONTRE LES COURSES HORIZONTALES OU VERTICALES ET LES COUDES. GARDEZ-LA TENDUE. DES ESPACEURS SONT FIXÉS À LA GAINE FLEXIBLE INTÉRIEURE À INTERVALLES PRÉDÉTERMINÉS AFIN DE GARDER UN ESPACE VIDE ÉGAL AVEC LA GAINE FLEXIBLE EXTÉRIEURE. CET ESPACE EST REQUIS POUR QUE LE FONCTIONNEMENT SOIT SÉCURITAIRE.
  • Page 10 COUDES MULTIPLES Les installations à coudes multiples sont possibles jusqu’à un maximum de six coudes de 90°. COUDES V1+V2+V3+ V1+V2+V3+ MAXIMUM H1+H2+H3 H1+H2+H3 65 PIEDS 10 PIEDS SIX 90° ÉVACUATION VERTICALE DESCENDANTE MAX D COUDES H1+H2+V H1+H2+V MAXIMUM 65 PIEDS 10 PIEDS 8 PIEDS SIX 90°...
  • Page 11 Installation du Panneau de Contrôle 1. Identifi é toutes les fi ls pour prévenir confusion lorsque le panneau de contrôle doit être réinstallé. Débranchez toutes les fi ls du panneau de contrôle. note: Connexions des câbles ne rentrera pas dans des endroits désignés. 2.
  • Page 12 1. Enlever le fi l de dérivation (JP1) du panneau de contrôle. (Cela activera le fonction du terminaison mécanique). 2. Remplacer le couvercle du panneau de contrôle et toutes les connections de fi ls sauf le cordon d’alimentation (x1); cela sera remplacer avec le nouveau harnais de fi...

This manual is also suitable for:

Nappva-811xHd81