5.11.17 .3.8
Ta ble Entry Mo de S In t erro g atio n Mess age D ata
Command Syntax:
Description:
Table Entry:
Numeric:
Default:
Example:
Query:
Returns:
5.11.17 .3.9
Ta ble Entry Pu ls e Po wer Le vel
Command Syntax:
Description:
Table Entry:
Numeric:
Default:
Example:
Query:
Return:
NOTE:
139187 / Rev. 500
September 2021
{:RGS | :RGS2000NG}{:XPDR}{:ITABLE:}<table entry>{:UF}SP<numeric > C R
T his command sets the d ata messa ge fo r the Mode S Interrogatio n of the
s el ec te d ta ble en tr y .
1 to 32 (deci ma l ASCII)
Sho r t interrog ation 0 to FF FF FF FF FF FF FF (1 4 hexad ecimal ASCII)
Lo ng i n ter r o gat i on 0 t o FF FF FF FF FF FF F FF FF FF FF FF FF FF F ( 28
he xade ci ma l ASC II). T he last si x cha racte r s are the Mode S Addr e ss .
00 000 000 0000 01
:RGS:XPDR:ITABLE:1:UF 12 3456 789 ABC DE\r
: R G S: X P D R : I TA B L E : 1 : U F? \r
12 345 678 9ABCDE
{:RGS |:RGS2 000N G}{: XPDR}{:IT ABLE:}<tabl e e ntry> {:POW
|:POWER}SP<nume ric>CR
T his command sets t he an te nna po wer for the to p antenn a of t he ta ble en try
sel ecte d.
1 to 100 0 (d ecimal ASCII)
-90 T O -20 dBm (decimal ASCII)
- 20 d B m
: R G S: X P D R : I TA B LE:1:POW -31\r
:RGS:XPDR:ITABLE:1:POW?\r
-31.0
T he po wer l evel ran ge dep ends of th e p ower mode sel ected using t h e
pre v ious command .
RGS-2000NG TCAS Test Set Operation Manual