High-Performance Dual-CAN to Fiber Switch User Manual
2.2 Power Interfaces
CANSwitch-AF2S2 uses a 9-36 V DC power supply that is easily available at the
industrial site, and is equipped with two wiring ports. One is a round hole socket and the
other is a terminal block. Both interfaces support positive and negative connections, with
no need to confirm the positive and negative poles. Figure 2.4 shows its interface.

2.3 RS232 Configuration Interface

As shown in Figure 2.5, this interface is specially used to configure the
CANSwitch-AF2S2 device.
2.4 Reset Button, Default Restoration Button, and Function Switch
As shown in Figure 2.6, RESET is used to reset the device manually. Press it for 1
second to reset the device; DEF is used to restore factory settings. Press it for 5-10
seconds and then the system SYS is off (the SYS indicator is green). The device will
automatically reset factory settings. The CANSwitch-AF2S2 device has two functions:
Hub (hub) and Converter (converter). When the function switch is set to the corresponding
function, press the RESET key once for the function to take effect.
Figure 2.6 Reset button, default restoration button and function switch
Figure 2.4 Power Interface
Figure 2.5 Configuring ports
©2021 Guangzhou ZLG Electronics Technology Co.,Ltd.