NB18/NB24 Gas Log Set
3. When Set Temp. is 1° F higher than Room Temp.,
flame height will be on Low.
4. When Set Temp. is equal to Room Temp., flame height
does not change (stays on low).
5. When Set Temp. is lower than Room Temp., the fire-
place will be shut off.
6. When Set Temp. is 1° F higher than Room Temp.,
again the flame height will be on Low.
To exit Smart Mode and shut off the fireplace;
a. push and hold the THERMO button for 3 sec-
onds, Or
b. press the OFF button, Or
c. slide down on the arrow buttons.
To shut off the Smart Mode thermostat option and return
to regular thermostat mode, press and hold the THERMO
button and the ON/UP button at the same time for 3 sec-
onds again.
Setting up Blank Screen or Constant Display in Idle
Figure 63
There is an option to set up how the LCD displays and
functions when the transmitter is in idle. There are two
choices:
1. A) Mode. When
the transmitter is
in idle, the icons
in the "touch area"
(timer,
thermo-
stat and ON/OFF)
will disappear, as
shown in the figure
on the left. When
any of the touch
buttons is pressed,
those icons will ap-
pear and are ready
to operate (default).
2. B) Mode. The transmitter always displays all available
icons showing current status of timer and thermostat
as shown in the figure on the right.
Press TIMER and THERMO buttons at the same time for
3 seconds to toggle between A) and B).
1. When the current setting is A), touch any place in the
touch area to bring up the icons then press TIMER but-
ton and THERMO button at the same time for 3 sec-
onds. The backlight will flash once to indicate that the
setting has changed to B).
2. When the current setting is B), pressing TIMER button
and THERMO button at the same time for 3 seconds
will switch to A) Mode. The touch area icons will disap-
pear.
Monessen • NB18/24 Gas Log Set Installation/Owner's Manual • 81D0107 • Rev B • 09/16
TOUCH SCREEN REMOTE CONTROL OPERATION—SCR MODELS
Figure 63
FP2666
display
n Safety Features
1. Low Battery Detection
When low battery condition occurs, the trans-
mitter will turn off the fireplace.
A) Battery voltage is checked every one min-
ute. When the battery voltage is low, the
LCD displays a low battery icon which will exist in
all modes.
B) The transmitter will not operate with low battery
voltage. Change the batteries before the batteries
become too weak for normal operations.
2. Power On Initialization
After the power-on initialization, the transmitter sends
a signal to turn off the fireplace.
3. Thermal Shutdown
When the ambient temperature is more than 99°F, the
transmitter will turn off the fireplace.
A) The LCD will display "HI".
B) The Transmitter will not function until
the room temperature has dropped be-
low 99 degree Fahrenheit.
4. Low Temperature Condition
When the ambient temperature is less than 40 degrees
Fahrenheit, the LCD will display "LO", and NO SIGNAL
will be sent to turn on the appliance.
All functions still remain the same for
both Manual Mode and Thermostat
Mode
5. Child-proof Protection
The child-proof icon will be shown when
the child-proof mode is activated by
pressing the ON button and the OFF
button at the same time for three sec-
onds.
A) Enter childproof mode by pressing
and holding both the ON button and the OFF button
simultaneously for 3 seconds. The Childproof indi-
cator will be shown on the LCD.
B) Deactivate childproof mode by pressing and hold-
ing the ON button and the OFF button simultane-
ously for 3 seconds again. The Childproof indicator
disappears on the LCD.
C) The transmitter cannot be operated in childproof
mode.
FP2612
low batter
FP2613
HI
FP2614
lo no child
39