Electrical Wiring - Millivolt; Connect Optional Wall Switch Or Thermostat - Monessen Hearth BO18-R Installation And Operating Instructions Manual

Vented/unvented gas log set for nb18, nb24, nb18scr, nb24scr
Table of Contents

Advertisement

ELECTRICAL WIRING - MILLIVOLT

Label all wires prior to disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation. Verify
proper operation after servicing.
The millivolt valve is a self-powered combination gas con-
trol THAT DOES NOT REQUIRE 110 VAC TO OPERATE.
On/Off Switch
or Optional Wall
Switch, Remote
or T-Stat
Figure 16 -
Wiring Diagram
NOTE: Log switch wires are not factory connected. Connect log switch wires to the TH/TP and TH valve terminals as
shown.
Monessen • NB18/24 Gas Log Set Installation/Owner's Manual • 81D0107 • Rev B • 09/16
14
TH = 3
TP = 1
TP/TH = 2
Log Switch
FP2267
wiring diagram
CONNECT OPTIONAL WALL SWITCH OR
THERMOSTAT
1. Use 18 awg, two-wire cable, 15 feet maximum length.
2. At one end of the cable, connect both wires to the wall
switch or thermostat. At the other end, connect one
wire to TP/TH and one wire to TH, or connect the wall
switch/thermostat to the two male (0.25") terminals on
the left side of the unit. The color of the wires does not
matter.
ODS
Pilot
Millivolt
Valve
NB18/NB24 Gas Log Set
ODS Pilot

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bo18-fBo24-rBo24-fBo30-rBo30-f

Table of Contents