Cooling When The Gs4000 Is Set On A Desk Or Table - Hitachi GS4000 Series Installation Manual

Hide thumbs Also See for GS4000 Series:
Table of Contents

Advertisement

(4) GS4000-160E2 Air Flow
Out
Figure 2.10-4 GS4000-160E2 Air Flow
(5) GS4000-320E (AC)/GS4000-320E (DC) Air Flow
Out
Figure 2.10-5 GS4000-320E Air Flow

2.10.2 Cooling When the GS4000 Is Set On a Desk or Table

To ensure the air flow, reserve at least 70 mm of space from the ventilation slots of each side
of the device.
*
520-10-026-30X
WARNING: DO NOT BLOCK THE VENTILATION SLOTS. IF YOU BLOCK THE
VENTILATION SLOTS, THE INSIDE OF THE DEVICE WILL OVERHEAT AND
COULD CAUSE A FIRE. RESERVE AT LEAST 70 MM OF SPACE FROM THE
VENTILATION SLOTS OF EACH DEVICE TO ENSURE PROPER AIR FLOW
THROUGH THE VENTILATION SLOTS.
NOTE: If you locate other devices with fans near the GS4000, the air flow from those
units may interfere with others. In an extreme case, this could cause the device
to overheat and fail. Therefore, remember to keep adequate space between
interfering units. You may also install a partition between devices to prevent the
air flow of one device from blocking the other. If you install a partition, locate it
more than 70mm away from the device.
In
In
GS4000 Installation Guide Revision 4.00
2-25